A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improvement of the desulfurization and regeneration properties through the control of pore structures of the Zn-Ti-based H2S removal sorbents. | LitMetric

To improve the sulfur removing capacity of the conventional Zn-Ti-based H2S removal sorbents, a new Zn-Ti based sorbent (ZT-cp) was prepared by the coprecipitation method and tested in a packed bed reactor at middle temperature conditions (H2S absorption at 480 degrees C, regeneration at 580 degrees C). The new Zn-Ti-based sorbent showed excellent sulfur removing capacity without deactivation, even after 10 cycles of absorption and regeneration. The conventional Zn-Ti-based sorbents (ZT-700, ZT-1000), however, that were prepared by physical mixing, were continuously deactivated. In particular, the initial sulfur removing capacity of the ZT-cp sorbent showed a very high absorption value (0.22 g S/g sorbent), which corresponded to 91.6% of theoretical absorption amount. These results can be explained by the difference in physical properties such as pore volume, surface area, and particle size. It was also found that the sulfides formed from the ZT-cp and ZT-1000 sorbents with spinel structure were easily regenerated even at 580 degrees C. Those from the ZT-700 sorbent, with separated ZnO and TiO2 structures, needed a temperature higher than 610 degrees C for regeneration.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es050966gDOI Listing

Publication Analysis

Top Keywords

sulfur removing
12
removing capacity
12
zn-ti-based h2s
8
h2s removal
8
removal sorbents
8
conventional zn-ti-based
8
degrees regeneration
8
580 degrees
8
sorbent
5
improvement desulfurization
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!