Spherical aberration of heavily pumped Nd:YAG rods was corrected by use of spherical relay optics selected to add conjugate amounts of aberration. Wavefront measurements showed elimination of spherical aberration. Correction of spherical aberration allowed 250 W of power to be generated in a radially polarized, birefringence-free oscillator (60% more power than without correction). Scale-up of wavefront maintenance was demonstrated in a two-rod amplifier module (6.3 kW electrical pump power). Radial polarization and spherical aberration correction together eliminated the main aberrations in uniformly pumped rod-based lasers. Rotating adjacent pump chambers substantially reduced the multifold aberrations induced by nonuniformity of the azimuthal pumps. DeltaM2 in the radially polarized beam was 0.3 and 1.4 with and without aberration correction, respectively, in each two-pump chamber module. Analysis predicts further improvements when higher-order aberration correction is applied.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.44.007823DOI Listing

Publication Analysis

Top Keywords

spherical aberration
16
aberration correction
16
radially polarized
12
correction spherical
8
aberration
7
correction
6
spherical
5
spherical azimuthal
4
azimuthal aberrations
4
aberrations radially
4

Similar Publications

SMILE for correction of myopia in patients during the incipient phase of presbyopia.

Int Ophthalmol

January 2025

Department of Ophthalmology, Peking University Third Hospital, No 49 Huayuan North Road, Haidian District, Beijing, 100191, China.

Purpose: To evaluate clinical outcomes and visual quality 12 months after small incision lenticule extraction (SMILE) for correction of myopia with or without astigmatism in patients during the incipient phase of presbyopia.

Setting: Peking University Third Hospital, Beijing, China.

Design: Retrospective observation study.

View Article and Find Full Text PDF

Significance: Visual acuity (VA) depends on many factors. When the goal is to assess retinal health rather than performance, then using a 3-mm pupil reduces unwanted wavefront aberrations. The axis of astigmatism can still potentially change with age.

View Article and Find Full Text PDF

We theoretically demonstrate that ponderomotive interactions near the electron cross-over can be used for aberration correction in ultrafast electron microscopes. Highly magnified electron shadow images from SiN thin films are utilized to visualize the distortions induced by spherical aberrations. Our simulations of electron-light interactions indicate that spherical aberrations can be compensated resulting in an aberration-free angle of 8.

View Article and Find Full Text PDF

Specimen-induced aberrations limit the penetration depth of standard optical imaging techniques in vivo, mainly due to the propagation of high NA beams in a non-homogenous medium. Overcoming these limitations requires complex optical imaging systems and techniques. Implantable high NA micro-optics can be a solution to tissue induced spherical aberrations, but in order to be implanted, they need to have reduced complexity, offering a lower surface to the host immune reaction.

View Article and Find Full Text PDF

In the last few years, new ways of structuring light have emerged, with the potential to be used in a wide variety of applications, including materials processing, micro-particle manipulation and charged particle acceleration. One of these techniques is the structured laser beam (SLB). The important advantages of this beam are the simple generation principle using spherical aberration and the potentially infinite propagation range.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!