Background: The use of self-expandable metallic stents in the management of obstructing colorectal cancer has been described with increasing frequency in the literature. Our goal was to evaluate the efficacy and associated morbidity of the use of self-expandable metallic stents to relieve colorectal obstruction at our institution.

Methods: A retrospective chart review of patients who underwent colorectal stent placement between December 2001 and December 2003 in a tertiary referral center was performed.

Results: Stents were placed successfully in 17 of 21 patients (81%) with colorectal obstruction. Placement was achieved endoscopically in 13 patients and radiologically in 4. Ten self-expandable metallic stents were used as a bridge to surgery, and 7 were used for palliation. The obstructions were located in the sigmoid colon (11 patients), the rectosigmoid (3), the splenic flexure, the hepatic flexure, and the rectum. Malignant obstruction was noted in 14 patients. One patient with malignancy experienced a sigmoid perforation, and 2 patients with benign disease had complications (1 stent migration and 1 re-obstruction). Stent patency in obstruction secondary to colonic adenocarcinoma was 100% in our follow-up period (range, 5 to 15 months).

Conclusions: The use of stents as a bridge to surgery is associated with low morbidity, allows for bowel preparation, and thus avoids the need for a temporary colostomy. Long-term patency suggests that stents may allow for the avoidance of an operation in patients with metastatic disease and further defines their role in the palliation of malignant obstruction. Further prospective randomized studies are necessary to fully elucidate the use of stents in the management of colorectal cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015633PMC

Publication Analysis

Top Keywords

metallic stents
16
stents management
12
colorectal obstruction
12
self-expandable metallic
12
stents
8
management colorectal
8
colorectal cancer
8
stents bridge
8
bridge surgery
8
malignant obstruction
8

Similar Publications

Introduction: Reports of pseudoaneurysms associated with biliary self-expandable metallic stent (SEMS) placement have been increasing. Recently, cases of hepatic pseudoaneurysm rupture caused by double pigtail plastic stents (DPS) have also been reported. The symptoms of pseudoaneurysms are often non-specific, and many cases are diagnosed only after rupture.

View Article and Find Full Text PDF

Background: First-generation bioresorbable scaffolds (BRS) increased risks of stent thrombosis and adverse events. The Bioheart scaffold is a new poly-L-lactic acid-based BRS.

Objectives: This study sought to evaluate the efficacy and safety of the BRS in patients with coronary artery disease.

View Article and Find Full Text PDF

Background: The risk-benefit ratio of the Absorb bioresorbable vascular scaffold (BVS) may vary before and after 3 years, the time point of complete bioresorption of the poly-L-lactic acid scaffold.

Objectives: The aim of this study was to determine the time-varying outcomes of the Absorb BVS compared with cobalt-chromium everolimus-eluting stents (EES) from a large individual-patient-data pooled analysis of randomized trials.

Methods: The individual patient data from 5 trials that randomized 5,988 patients undergoing percutaneous coronary intervention to the Absorb BVS vs EES with 5-year follow-up were pooled.

View Article and Find Full Text PDF