A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid discrimination of fatty acid composition in fats and oils by electrospray ionization mass spectrometry. | LitMetric

Rapid discrimination of fatty acid composition in fats and oils by electrospray ionization mass spectrometry.

Anal Sci

Criminal Investigation Laboratory, Metropolitan Police Department, Chiyoda, Tokyo 100-8929, Japan.

Published: December 2005

Fatty acids in 42 types of saponified vegetable and animal oils were analyzed by electrospray ionization mass spectrometry (ESI-MS) for the development of their rapid discrimination. The compositions were compared with those analyzed by gas chromatography-mass spectrometry (GC-MS), a more conventional method used in the discrimination of fats and oils. Fatty acids extracted with 2-propanol were-detected as deprotonated molecular ions ([M-H]-) in the ESI-MS spectra of the negative-ion mode. The composition obtained by ESI-MS corresponded to the data of the total ion chromatograms by GC-MS. The ESI-MS analysis discriminated the fats and oils within only one minute after starting the measurement. The detection limit for the analysis was approximately 10(-10) g as a sample amount analyzed for one minute. This result showed that the ESI-MS analysis discriminated the fats and oils much more rapidly and sensitively than the GC-MS analysis, which requires several tens of minutes and approximately 10(-9) g. Accordingly, the ESI-MS analysis was found to be suitable for a screening procedure for the discrimination of fats and oils.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.21.1457DOI Listing

Publication Analysis

Top Keywords

fats oils
20
esi-ms analysis
12
rapid discrimination
8
electrospray ionization
8
ionization mass
8
mass spectrometry
8
fatty acids
8
discrimination fats
8
analysis discriminated
8
discriminated fats
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!