A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated DNA fragments recognition and sizing through AFM image processing. | LitMetric

Automated DNA fragments recognition and sizing through AFM image processing.

IEEE Trans Inf Technol Biomed

Politecnico di Torino, DAUIN, Italy.

Published: December 2005

This paper presents an automated algorithm to determine DNA fragment size from atomic force microscope images and to extract the molecular profiles. The sizing of DNA fragments is a widely used procedure for investigating the physical properties of individual or protein-bound DNA molecules. Several atomic force microscope (AFM) real and computer-generated images were tested for different pixel and fragment sizes and for different background noises. The automated approach minimizes processing time with respect to manual and semi-automated DNA sizing. Moreover, the DNA molecule profile recognition can be used to perform further structural analysis. For computer-generated images, the root mean square error incurred by the automated algorithm in the length estimation is 0.6% for a 7.8 nm image pixel size and 0.34% for a 3.9 nm image pixel size. For AFM real images we obtain a distribution of lengths with a standard deviation of 2.3% of mean and a measured average length very close to the real one, with an error around 0.33%.

Download full-text PDF

Source
http://dx.doi.org/10.1109/titb.2005.855546DOI Listing

Publication Analysis

Top Keywords

dna fragments
8
automated algorithm
8
atomic force
8
force microscope
8
sizing dna
8
afm real
8
computer-generated images
8
image pixel
8
pixel size
8
dna
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!