Background: Although the continuity equation remains the noninvasive standard, planimetry using transesophageal echocardiography is often used to assess valve area for patients with aortic stenosis (AS). Not uncommonly, however, anatomic valve area (AVAA) obtained by planimetry overestimates continuity-derived effective valve area (AVAE) in bicuspid AS.
Methods: Transthoracic Doppler and transesophageal echocardiography were performed to obtain AVAE and AVAA in 31 patients with bicuspid AS (age 61 +/- 11 years) and 22 patients with degenerative tricuspid AS (age 71 +/- 13 years). Aortic root and left ventricular outflow tract dimensions and the directional angle of the stenotic jet were assessed in all patients. Using these data, a computational fluid dynamics model was constructed to test the effect of these variables in determining the relationship between AVAE and AVAA.
Results: For patients with tricuspid AS, the correlation between AVAA (1.15 +/- 0.36 cm2) and AVAE (1.13 +/- 0.46 cm2) was excellent (r = 0.91, P < .001, Delta = 0.02 +/- 0.21 cm2). However, AVAA was significantly larger (1.19 +/- 0.35 cm2) than AVAE (0.89 +/- 0.29 cm2) in the bicuspid AS group (r = 0.71, P < .001, Delta = 0.29 +/- 0.25 cm2). Computer simulation demonstrated that the observed discrepancy related to jet eccentricity.
Conclusion: For a given anatomic orifice, functional severity tends to be greater in bicuspid AS than in tricuspid AS. This appears to be primarily related to greater jet eccentricity and less pressure recovery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2005.04.005 | DOI Listing |
Medicina (Kaunas)
December 2024
Pathology Unit, Department of Precision and Regenerative Medicine and Ionian Area, University of Bari "Aldo Moro", 70121 Bari, Italy.
Chromosomal abnormalities (CAs) are changes in the number or structure of chromosomes, manifested as alterations in the total number of chromosomes or as structural abnormalities involving the loss, duplication, or rearrangement of chromosomal segments. CAs can be inherited or can occur spontaneously, leading to congenital malformations and genetic diseases. CAs associated with cardiovascular diseases cause structural or functional alterations of the heart, affecting the cardiac chambers, valves, coronary arteries, aorta, and cardiac conduction, thus increasing the likelihood of arrhythmias, cardiac arrest, and sudden cardiac death (SCD).
View Article and Find Full Text PDFInt J Cardiol
January 2025
Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy; Vita Salute San Raffaele University, Milan, Italy.
Background: Left ventricular obstruction (LVO) is an infrequent complication following transcatheter aortic valve replacement (TAVR) that can lead to severe hemodynamic decompensation. Previous studies have analyzed the pathophysiology of this clinical entity; however, little is known about the anatomical characteristics as assessed by computational tomography (CT) of patients at risk.
Methods: Data from 349 patients were retrospectively analyzed from a single center registry of patients undergoing TAVR at San Raffaele Hospital, Milan, Italy, between January 2020 and December 2021.
Catheter Cardiovasc Interv
January 2025
Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Transcatheter mitral valve replacement (TMVR) may emerge as a surgical alternative for high-risk patients with severe mitral annular calcification (MAC), yet several questions remain to be addressed. We present the case of a 67-year-old high-risk female patient with severe MAC (MAC score = 8) and mitral stenosis (effective orifice area = 121.3 mm).
View Article and Find Full Text PDFAnatol J Cardiol
January 2025
Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA ; Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA.
Background: To evaluate the clinical outcomes of valve-in-valve transcatheter aortic valve replacement (ViV TAVR) with newer-generation self-expanding Evolut valves according to the size of the failed surgical bioprosthesis.
Methods: This single-center retrospective study evaluated consecutive patients undergoing ViV TAVR with the Evolut Pro/Pro+/Fx between 2018 and 2022. These patients were compared based on the true internal diameter (ID) of the failed bioprosthesis, specifically ≤19 mm (small group) vs.
Cardiovasc Interv Ther
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan.
Transcatheter aortic valve implantation (TAVI) using the NAVITOR system has been relatively underreported due to its recent introduction in Japan. This study aimed to assess the short-term outcomes of TAVI with the NAVITOR in real-world clinical practice. Patients with severe aortic stenosis who underwent TAVI using the NAVITOR system at our institution between December 2022 and December 2023 were prospectively enrolled.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!