Objectives: Our study was designed to demonstrate that transesophageal echocardiography using a 3.3-mm monoplane probe can accurately evaluate the left atrium for patients with arrhythmias before cardioversion.

Background: Standard probes cause discomfort during intubation requiring sedation, but miniature probes do not.

Methods: With topical anesthesia alone, a 3.3-mm probe was used for transesophageal echocardiography in 60 patients. After intravenous sedation, standard transesophageal echocardiography was then performed.

Results: In 51 of 60 patients, the left atrium was visualized with the 3.3-mm probe. In 43 of 51 patients the appendage was clear. A thrombus was seen in 7 patients on both studies. In one patient spontaneous echocontrast was seen only with the 3.3-mm probe (sensitivity 100%, specificity 97%). In 9 of 60 patients, the appendage could not be assessed.

Conclusions: In many patients the 3.3-mm probe can visualize the appendage and obviate the need for sedation. Technical advances will improve image quality with miniature probes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2005.05.007DOI Listing

Publication Analysis

Top Keywords

33-mm probe
16
transesophageal echocardiography
12
33-mm monoplane
8
monoplane probe
8
left atrium
8
miniature probes
8
patients appendage
8
patients
7
33-mm
6
probe
6

Similar Publications

Objective: To evaluate the clinical efficacy of clear aligner therapy in patients with severe periodontitis accompanied by pathological tooth displacement in the anterior region.

Methods: This retrospective study analyzed patients diagnosed with severe periodontitis and pathological displacement in the anterior region, who visited both the Periodontics and Orthodontics Departments at Peking University School and Hospital of Stomatology between 2019 and 2022. A total of 26 eligible cases were included in this study.

View Article and Find Full Text PDF

Head pose-assisted localization of facial landmarks for enhanced fast registration in skull base surgery.

Comput Med Imaging Graph

December 2024

School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, Beijing, PR China; Zhengzhou Research Institute, Beijing Institute of Technology, Zhengzhou, 450000, Henan, PR China. Electronic address:

In skull base surgery, the method of using a probe to draw or 3D scanners to acquire intraoperative facial point clouds for spatial registration presents several issues. Manual manipulation results in inefficiency and poor consistency. Traditional registration algorithms based on point clouds are highly dependent on the initial pose.

View Article and Find Full Text PDF

Osseointegration along with better mimicry of natural bone behaviour addresses the long-term performance of artificial intervertebral disc prosthesis. Here the effect of a novel artificial intervertebral disc geometry on stress, deformation and strain on lumbar segments to restore movement of the spine was investigated. The process involved, using CT image data, and solid modelling, simulation-driven design and finite element (FE) analysis, hexahedral mesh sensitivity analysis, implant placements.

View Article and Find Full Text PDF

Context The underlying principle of guided tissue regeneration (GTR) lies in the use of barrier membranes. Their role is key to this method, as they inhibit the rapid growth of epithelial and connective tissue cells, thus isolating the infrabony defects (IBDs) and ensuring the regeneration of slower-growing periodontal structures. The main disadvantages of resorbable membranes are related to their limited time of action and the need to use them in two layers, which increases the chance of a postoperative complication, i.

View Article and Find Full Text PDF

Objective This study aims to investigate the utility of handheld, Bluetooth-capable ultrasound in identifying millimeter-sized vasculature in both living and cadaveric subjects. Methods Using handheld, linear ultrasound probes, the carpal tunnel of 87 living individuals (174 forearms) was assessed for the presence of a persistent median artery (PMA). Radial, ulnar, and persistent median arterial diameters were measured, along with forearm circumference.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!