Objectives: Our study was designed to demonstrate that transesophageal echocardiography using a 3.3-mm monoplane probe can accurately evaluate the left atrium for patients with arrhythmias before cardioversion.
Background: Standard probes cause discomfort during intubation requiring sedation, but miniature probes do not.
Methods: With topical anesthesia alone, a 3.3-mm probe was used for transesophageal echocardiography in 60 patients. After intravenous sedation, standard transesophageal echocardiography was then performed.
Results: In 51 of 60 patients, the left atrium was visualized with the 3.3-mm probe. In 43 of 51 patients the appendage was clear. A thrombus was seen in 7 patients on both studies. In one patient spontaneous echocontrast was seen only with the 3.3-mm probe (sensitivity 100%, specificity 97%). In 9 of 60 patients, the appendage could not be assessed.
Conclusions: In many patients the 3.3-mm probe can visualize the appendage and obviate the need for sedation. Technical advances will improve image quality with miniature probes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2005.05.007 | DOI Listing |
Beijing Da Xue Xue Bao Yi Xue Ban
February 2025
Department of Orthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China.
Objective: To evaluate the clinical efficacy of clear aligner therapy in patients with severe periodontitis accompanied by pathological tooth displacement in the anterior region.
Methods: This retrospective study analyzed patients diagnosed with severe periodontitis and pathological displacement in the anterior region, who visited both the Periodontics and Orthodontics Departments at Peking University School and Hospital of Stomatology between 2019 and 2022. A total of 26 eligible cases were included in this study.
Comput Med Imaging Graph
December 2024
School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, Beijing, PR China; Zhengzhou Research Institute, Beijing Institute of Technology, Zhengzhou, 450000, Henan, PR China. Electronic address:
In skull base surgery, the method of using a probe to draw or 3D scanners to acquire intraoperative facial point clouds for spatial registration presents several issues. Manual manipulation results in inefficiency and poor consistency. Traditional registration algorithms based on point clouds are highly dependent on the initial pose.
View Article and Find Full Text PDFJ Clin Neurosci
February 2025
Laser Additive Manufacturing Laboratory, Laser Technology Division, Raja Ramanna Centre for Advanced Technology, Indore, Madhya Pradesh 452013, India.
Osseointegration along with better mimicry of natural bone behaviour addresses the long-term performance of artificial intervertebral disc prosthesis. Here the effect of a novel artificial intervertebral disc geometry on stress, deformation and strain on lumbar segments to restore movement of the spine was investigated. The process involved, using CT image data, and solid modelling, simulation-driven design and finite element (FE) analysis, hexahedral mesh sensitivity analysis, implant placements.
View Article and Find Full Text PDFCureus
October 2024
Department of Periodontology and Dental Implantology, Medical University of Varna, Varna, BGR.
Context The underlying principle of guided tissue regeneration (GTR) lies in the use of barrier membranes. Their role is key to this method, as they inhibit the rapid growth of epithelial and connective tissue cells, thus isolating the infrabony defects (IBDs) and ensuring the regeneration of slower-growing periodontal structures. The main disadvantages of resorbable membranes are related to their limited time of action and the need to use them in two layers, which increases the chance of a postoperative complication, i.
View Article and Find Full Text PDFCureus
August 2024
Department of Anatomical Sciences, Liberty University College of Osteopathic Medicine, Lynchburg, USA.
Objective This study aims to investigate the utility of handheld, Bluetooth-capable ultrasound in identifying millimeter-sized vasculature in both living and cadaveric subjects. Methods Using handheld, linear ultrasound probes, the carpal tunnel of 87 living individuals (174 forearms) was assessed for the presence of a persistent median artery (PMA). Radial, ulnar, and persistent median arterial diameters were measured, along with forearm circumference.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!