A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Laboratory model of tissue adhesive (2-octyl cyanoacrylate) in sealing clear corneal cataract wounds. | LitMetric

Laboratory model of tissue adhesive (2-octyl cyanoacrylate) in sealing clear corneal cataract wounds.

Am J Ophthalmol

Department of Ophthalmology, The New York Eye & Ear Infirmary, 310 E. 14th Street, New York, NY 10003, USA.

Published: December 2005

Purpose: To determine the efficacy of a tissue adhesive (2-octyl cyanoacrylate with parabens; Liquid Bandage, Johnson & Johnson, Skillman, New Jersey) in sealing clear corneal cataract wounds.

Design: Laboratory investigation.

Methods: Seven human donor globes were prepared for Miyake video microscopy. A 3.0-mm clear corneal incision was created. A transscleral cannula was inserted and connected to a bottle of saline. The bottle height was varied to alter intraocular pressure. Droplets of India ink were placed on the wound. Main outcome measure was any influx of India ink into the anterior chamber as viewed through the Miyake system with intraocular pressure (IOP) fluctuation or with manual pressure. If India ink was present in the eye, it was irrigated out, and the experiment was repeated with IOP fluctuation and manual pressure after the application of 2-octyl cyanoacrylate to the wound.

Results: One eye demonstrated the presence of India ink inside the eye on IOP reduction to <5 mm Hg. Three eyes demonstrated the presence of India ink inside the eye with manual pressure. Three eyes did not leak with manual pressure or IOP variation. All seven eyes without glue leaked with exaggerated manual pressure at the wound edge. Of the seven eyes with tissue adhesive, none demonstrated influx of India ink with IOP variation or manual wound manipulation.

Conclusions: Our laboratory model demonstrates that 2-octyl cyanoacrylate prevents the influx of ocular surface fluid independent of IOP and manual wound manipulation. Further investigations in clinical models are necessary to determine the future use of this adhesive barrier substance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2005.06.055DOI Listing

Publication Analysis

Top Keywords

india ink
16
2-octyl cyanoacrylate
12
clear corneal
12
tissue adhesive
8
adhesive 2-octyl
8
sealing clear
8
corneal cataract
8
intraocular pressure
8
iop fluctuation
8
fluctuation manual
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!