A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cardiac microimpedance measurement in two-dimensional models using multisite interstitial stimulation. | LitMetric

Cardiac microimpedance measurement in two-dimensional models using multisite interstitial stimulation.

Am J Physiol Heart Circ Physiol

Cardiac Rhythm Management Laboratory, Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA.

Published: May 2006

We analyzed central interstitial potential differences during multisite stimulation to assess the feasibility of using those recordings to measure cardiac microimpedances in multidimensional preparations. Because interstitial current injected and removed using electrodes with different proximities allows modulation of the portion of current crossing the membrane, we hypothesized that multisite interstitial stimulation would give rise to central interstitial potential differences that depend on intracellular and interstitial microimpedances, allowing measurement of those microimpedances. Simulations of multisite stimulation with fine and wide spacing in two-dimensional models that included dynamic membrane equations for guinea pig ventricular myocytes were performed to generate test data ( partial differentialphio). Isotropic interstitial and intracellular microimpedances were prescribed for one set of simulations, and anisotropic microimpedances with unequal ratios (intracellular to interstitial) along and across fibers were prescribed for another set of simulations. Microimpedance measurements were then obtained by making statistical comparisons between partial differentialphio values and interstitial potential differences from passive bidomain simulations (Deltaphio) in which a wide range of possible microimpedances were considered. Possible microimpedances were selected at 25% increments. After demonstrating the effectiveness of the overall method with microimpedance measurements using one-dimensional test data, we showed microimpedance measurements within 25% of prescribed values in isotropic and anisotropic models. Our findings suggest that development of microfabricated devices to implement the procedure would facilitate routine measurement as a component of cardiac electrophysiological study.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpheart.01180.2005DOI Listing

Publication Analysis

Top Keywords

interstitial potential
12
potential differences
12
microimpedance measurements
12
interstitial
9
two-dimensional models
8
multisite interstitial
8
interstitial stimulation
8
central interstitial
8
multisite stimulation
8
intracellular interstitial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!