A new instrument for coniotomy was developed and tested with cadaver experiments. The instrument should be simple, easy to handle, and should not have the various drawbacks of the existing devices. The new instrument was tested by 17 medical students and medical doctors on fresh human cadavers. We measured the time necessary for performing a successful experiment. It lasted 5-28 sec (mean value 22 sec) depending on the experience of the people carrying out the tests. This time is much shorter than with other existing instruments tested under experimental conditions. The instrument consists of a tube and a trocar with a small knife on the tip. The knife is used to incise the skin over the cricothyroid ligament and to perforate this ligament in sagittal position. The tube is provided with a plastic stripe, which limits the depth of the entrance of the instrument into the larynx and can also be used to attach the tube to the neck of the patient. After entering the larynx, the tube can be connected to an inflating bag. The correct seat of the tube was tested by inflation, with a calibrated probe or with laryngoscopy. The results of our tests encourage the development of this new instrument for industrial production.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ca.20263DOI Listing

Publication Analysis

Top Keywords

instrument
6
tube
5
device cricothyroidotomy
4
cricothyroidotomy instrument
4
instrument coniotomy
4
coniotomy developed
4
tested
4
developed tested
4
tested cadaver
4
cadaver experiments
4

Similar Publications

Development and validation of the infant nursing assessment scale: Results from exploratory factor analysis and Rasch modeling.

J Pediatr Nurs

January 2025

University of Padua, Laboratory of Studies and Evidence Based Nursing, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Padua, Italy.

Purpose: The primary challenge in infant care is developing a comprehensive, rapid, and reliable assessment tool that is minimally dependent on subjective evaluations and applicable in various inpatient settings. This study aims to develop and assess the structural validity of the Infant Nursing Assessment Scale (INA), enabling a comprehensive evaluation of hospitalized newborns and infants.

Design And Methods: A development and validation study based on cross-sectional design was undertaken.

View Article and Find Full Text PDF

Solvent-modulated preparation of lead-free CsBiIpolycrystalline film for high-performance photodetectors.

Nanotechnology

January 2025

School of Instrumentation Science and Opto-electronics Engineering, Beijing Information Science and Technology University, 12 Qinghe Xiaoying East Road, Xisanqi Street, Haidian District, Beijing, Beijing, 100192, CHINA.

Lead-free cesium bismuth iodide (CsBiI) perovskite exhibits extraordinary optoelectronic properties and attractive potential in various optoelectronic devices, especially the application for photodetectors. However, most CsBiIphotodetectors demonstrated poor detection performance due to the difficulty in obtaining high-quality polycrystalline films. Therefore, it makes sense to modulate the preparation of high-quality CsBiIpolycrystalline films and expand its applications.

View Article and Find Full Text PDF

To evaluate the accuracy of home self-monitoring portable blood glucose meters, we analyzed the current problems of patients using portable blood glucose meters and put forward reasonable suggestions. A self-designed questionnaire was used to survey 142 patients and 132 healthcare professionals. The questionnaire consisted of 16 items with an overall score ranging from 1 to 13 (with a higher score indicating better experience).

View Article and Find Full Text PDF

Ultrasensitive Detection of Circulating Plasma Cells Using Surface-Enhanced Raman Spectroscopy and Machine Learning for Multiple Myeloma Monitoring.

Anal Chem

January 2025

Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education, Fujian Provincial Key Laboratory of Photonics Technology, Fujian Normal University, Fuzhou, Fujian 350117, China.

Multiple myeloma is a hematologic malignancy characterized by the proliferation of abnormal plasma cells in the bone marrow. Despite therapeutic advancements, there remains a critical need for reliable, noninvasive methods to monitor multiple myeloma. Circulating plasma cells (CPCs) in peripheral blood are robust and independent prognostic markers, but their detection is challenging due to their low abundance.

View Article and Find Full Text PDF

Background: Prevalences of mental disorders are increasing worldwide. However, many people with mental health problems do not receive adequate treatment. An important factor preventing individuals from seeking professional help is negative attitudes toward psychotherapeutic treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!