Single-bounce hollow glass capillaries with ellipsoidal shapes have been used at the Cornell High Energy Synchrotron Source recently for various microbeam experiments, with focal spot sizes from 12 to 23 microm, divergences from 2 to 8 mrad, intensities up to 450 times the intensities of incident X-rays, and working distances up to 55 mm. Simple formulae are developed in this paper to explain capillary performance given the X-ray source size, capillary dimensions and slope errors. Capillary length is optimized for best focusing performance. Capillary fabrication accuracy is reported and capillary X-ray tests confirm the focusing properties expected from formulae. The application of capillaries to third-generation X-ray sources and future energy-recovery linac X-ray sources are discussed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1107/S0909049505038562 | DOI Listing |
J Am Chem Soc
January 2025
Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States.
Hydrogen spillover is an important process in catalytic hydrogenation reactions, facilitating H activation and modulating surface chemistry of reducible oxide catalysts. This study focuses on the unveiling of platinum-induced hydrogen spillover on monoclinic tungsten trioxide (γ-WO), employing ambient pressure X-ray photoelectron spectroscopy, density functional theory calculations and microkinetic modeling to investigate the dynamic evolution of surface states at varied temperatures. At room temperature, hydrogen spillover results in the formation of W and hydrogen intermediates (hydroxyl species and adsorbed water), facilitated by Pt metal clusters.
View Article and Find Full Text PDFBioelectromagnetics
January 2025
Seibersdorf Labor GmbH, Seibersdorf, Austria.
The electrical conductivity of human tissues is a major source of uncertainty when modelling the interactions between electromagnetic fields and the human body. The aim of this study is to estimate human tissue conductivities in vivo over the low-frequency range, from 30 Hz to 1 MHz. Noninvasive impedance measurements, medical imaging, and 3D surface scanning were performed on the forearms of ten volunteer test subjects.
View Article and Find Full Text PDFJ Gen Intern Med
January 2025
Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Trainees frequently present data, including vital signs, laboratory test results, and imaging results, just after the history or presenting illness in a section labeled "ED Course." This practice distracts from the history and physical and decenters the patient as the most valuable source of diagnostic data. Reformatting presentations to appropriately present objective data after the complete history may improve diagnosis and refocuses attention on the patient.
View Article and Find Full Text PDFSci Rep
January 2025
University Paris-Saclay, CEA, CNRS, Neurospin, Baobab UMR 9027, Gif-sur-Yvette, 91191, France.
Recent advances highlight the limitations of classification strategies in machine learning that rely on a single data source for understanding, diagnosing and predicting psychiatric syndromes. Moreover, approaches based solely on clinician labels often fail to capture the complexity and variability of these conditions. Recent research underlines the importance of considering multiple dimensions that span across different psychiatric syndromes.
View Article and Find Full Text PDFSci Rep
January 2025
Physical Chemistry Department, National Research Centre, 33 El Bohouth Street, P.O.12622, Dokki, Giza, Egypt.
Archaeological coins are considered essential sources of historical documentation. Over time, they are subjected to corrosion processes that gradually alter their appearance, shape, and composition. This study aims to evaluate the effects of the patina and/or protective coating on the corrosion process.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!