Sampling size in the verification of manufactured-supplied air kerma strengths.

Med Phys

Department of Oncology, Clínica Universitaria de Navarra, University of Navarra, Avda Pío XII s/n, Pamplona, Navarre, Spain.

Published: November 2005

Quality control mandate that the air kerma strengths (S(K)) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S(K) has a normal distribution. To demonstrate this, the S(K) of each of the seeds measured was corrected to ensure that the average S(K) of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2089627DOI Listing

Publication Analysis

Top Keywords

air kerma
8
kerma strengths
8
number seeds
8
seeds measured
8
seeds
5
sampling size
4
size verification
4
verification manufactured-supplied
4
manufactured-supplied air
4
strengths quality
4

Similar Publications

Background: Dynamic Coronary Roadmap (DCR) is a new PCI method that may reduce contrast dose and contrast-associated acute kidney injury (CA-AKI) risk. This paper evaluates DCR-guided PCI versus standard angiography PCI for contrast usage, procedure time, and CA-AKI risk.

Methods: On May 1, 2024, we searched PubMed, Scopus, Embase, Cochrane Library, and clinicaltrials.

View Article and Find Full Text PDF

Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).

Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.

View Article and Find Full Text PDF

Background: Dedicated breast computed tomography (bCT) systems offer detailed imaging for breast cancer diagnosis and treatment. As new bCT generations are developed, it is important to evaluate their imaging performance and dose efficiency to understand differences over previous models.

Purpose: To characterize the imaging performance and dose efficiency of a second-generation (GEN2) bCT system and compare them to those of a first-generation (GEN1) system.

View Article and Find Full Text PDF

Background: This retrospective study addresses the role of operator and fluoroscopy equipment in reducing patient radiation exposure in the Cath lab.

Methods: Data from 99,400 procedures performed in our institution between 2007 and 2019 were reviewed. Dosimetric parameters included reference point air kerma (K), Kerma Area Product (P), fluoroscopic time, and contrast volume.

View Article and Find Full Text PDF

Objective: The purpose of this study was to present a newly designed 3D-printed personalized model (3D PPM) of a radiofrequency needle guide with a maxillary fixation for gasserian ganglion (GG) puncture.

Methods: Implementation of 3D CT-guided radiofrequency therapy of the GG with and without use of 3D PPM was analyzed. The following parameters were assessed: radiation time, dose area product, air kerma reference point, pain severity during the puncture needle insertion, prosopalgia regression degree (according to visual analog scale) and the severity of facial numbness (according to the Barrow Neurological Institute scale) in the early postoperative period, and postpuncture complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!