Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Electron paramagnetic resonance (EPR) oximetry is a powerful technology that allows the monitoring of oxygenation in tissues. The measurement of tissue oxygenation can be achieved using lithium phthalocyanine (LiPc) crystals as oxygen reporters. In order to have biocompatibility for the sensing system and to assure long-term stability in the responsiveness of the system, we developed films of Teflon AF 2400 with embedded LiPc crystals. These systems can be used as retrievable inserts or parts of an implantable resonator or catheter. Atomic force microscopy studies revealed that the surface of the films was regular and planar. The response to oxygen of the sensor (EPR linewidth as a function of pO(2)) remained unchanged after implantation in mice, and was not affected by sterilization or irradiation. The use of resonators, holding LiPc embedded in Teflon AF 2400, implanted in the gastrocnemius muscle of rabbits allowed the monitoring of oxygen during several weeks. Several assays also demonstrated the biocompatibility of the system: (1) no hemolytic effect was noted; (2) no toxicity was found using the systemic injection test of extracts; (3) histological analysis in rabbit muscle in which the films were implanted for 1 week or 3 months was similar to standard polyethylene biocompatible devices. These advanced oxygen sensors are promising tools for future pre-clinical and clinical developments of EPR oximetry. These developments can be applied for other applications of biosensors where there is a need for oxygen permeable membranes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2005.03.009 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!