What is believed to be a novel phase-sensitive optical heterodyne interferometric ellipsometer is set up to characterize a twisted-nematic liquid crystal (TN-LC) by the elliptical parameters of the output polarization state. This ellipsometer presents the advantages of both polarized optical heterodyne interferometry and optical photometry, which introduce a polarization modulation that is capable of performing with high-sensitivity on phase detection in real time. The twist angle phi and the untwisted phase retardation gamma of TN-LC are measured precisely. The experimental results verify that a TN-LC can be treated as identical to an elliptical retarder.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.44.007509DOI Listing

Publication Analysis

Top Keywords

optical heterodyne
12
twisted-nematic liquid
8
liquid crystal
8
phase-sensitive optical
8
heterodyne interferometric
8
determination optical
4
optical parameters
4
parameters twisted-nematic
4
crystal phase-sensitive
4
optical
4

Similar Publications

The millimeter-wave wireless transmission system is widely regarded as a promising solution for applications of future 6G communication. This paper presents an experimental comparison between all-optical and all-electric receivers for millimeter-wave communication systems over a 15 m wireless link and demonstrates 200 m and 2 km real-time uncompressed HD video transmission using an all-optical transceiver at 100 GHz. The systems leverage photonics-assisted heterodyne beating techniques at the transmitter, while the receivers employ either an avalanche photodiode (APD)-based all-optical approach or an envelope detection-based all-electric approach.

View Article and Find Full Text PDF

Partial wave analysis is key to interpretation of the photoionization of atoms and molecules on the attosecond timescale. Here we propose a heterodyne analysis approach, based on the delay-resolved anisotropy parameters to reveal the role played by high-order partial waves during photoionization. This extends the Reconstruction of Attosecond Beating By Interference of Two-photon Transitions technique into the few-photon regime.

View Article and Find Full Text PDF

An ultra-narrow-linewidth laser is a core device in fields such as optical atomic clocks, quantum communications, and microwave photonic oscillators. This paper reports an ultra-narrow-linewidth self-injection locked semiconductor laser, which is realized through optical feedback from a high-Q (258 million) Fabry-Perot (FP) cavity constructed with three mirrors, generating an output power of 12 mW. Employing a delay self-heterodyne method based on a signal source analyzer, the phase noise of the laser is -129 dBc/Hz at 100 kHz offset frequency, with an intrinsic linewidth of 3 mHz.

View Article and Find Full Text PDF

Approaching the standard quantum limit of a Rydberg-atom microwave electrometer.

Sci Adv

December 2024

Key Laboratory of Atomic and Subatomic Structure and Quantum Control (Ministry of Education), Guangdong Basic Research Center of Excellence for Structure and Fundamental Interactions of Matter, School of Physics, South China Normal University, Guangzhou 510006, China.

The development of a microwave electrometer with inherent uncertainty approaching its ultimate limit carries both fundamental and technological significance. However, because of the thermal motion of atoms, the state-of-art Rydberg electrometer falls considerably short of the standard quantum limit by about three orders of magnitude. Here, we use an optically thin medium with approximately 5.

View Article and Find Full Text PDF

In-vessel design of a two-color heterodyne laser interferometer system for SPARC.

Rev Sci Instrum

December 2024

Commonwealth Fusion Systems, Devens, Massachusetts 01434, USA.

This article covers the in-vessel design of the SPARC interferometry diagnostic system, highlighting unique aspects of the systems design and port plug integration in preparation for "day-1" plasma operations as a critical diagnostic for density feedback control. An early decision for the diagnostic was to deploy two lasers in the infrared wavelength spectrum, allowing the system to have a higher optical throughput. The optimization of the in-vessel geometry for the diagnostic follows a similar approach, focusing on de-risking possible damage to the plasma facing optical components by moving them further from the plasma with an orientation that provides a greater possibility for protective features to be added.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!