A simple and rapid in situ preconcentration method for the spectrophotometric determination of trace ammonia nitrogen in environmental water samples has been developed based on solid-phase extraction using a small column packed with octadecyl group-bonded silica gel (Sep-Pak C18 cartridge). A water sample was taken into a graduated syringe for easy and simple operation and prevention of contamination immediately after sample collection. Ammonia in the sample was reacted with hypochlorite and thymol to be converted into indothymol blue; then the formed indothymol blue was collected as an ion pair between indothymol blue and tetrabutylammonium ion on a Sep-Pak C18 cartridge. The indothymol blue on the cartridge was stable for 4 days. The retained indothymol blue was easily eluted with a mixture of methanol and 0.01 mol/l sodium hydroxide solution. The color intensity due to the indothymol blue was spectrophotometrically measured at 725 nm. The proposed method was successfully applied to environmental water samples such as river water.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.21.1137DOI Listing

Publication Analysis

Top Keywords

indothymol blue
24
environmental water
12
water samples
12
simple rapid
8
rapid situ
8
situ preconcentration
8
preconcentration method
8
trace ammonia
8
ammonia nitrogen
8
nitrogen environmental
8

Similar Publications

Development of a polydimethylsiloxane-thymol/nitroprusside composite based sensor involving thymol derivatization for ammonium monitoring in water samples.

Sci Total Environ

January 2015

Departmento de Química Analítica Grupo MINTOTA, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain. Electronic address:

This report describes a polydimethylsiloxane (PDMS)-thymol/nitroprusside delivery composite sensor for direct monitoring of ammonium in environmental water samples. The sensor is based on a PDMS support that contains the Berthelot's reaction reagents. To prepare the PDMS-thymol/nitroprusside composite discs, thymol and nitroprusside have been encapsulated in the PDMS matrix, forming a reagent release support which significantly simplifies the analytical measurements, since it avoids the need to prepare derivatizing reagents and sample handling is reduced to the sampling step.

View Article and Find Full Text PDF

A simple and rapid in situ preconcentration method for the spectrophotometric determination of trace ammonia nitrogen in environmental water samples has been developed based on solid-phase extraction using a small column packed with octadecyl group-bonded silica gel (Sep-Pak C18 cartridge). A water sample was taken into a graduated syringe for easy and simple operation and prevention of contamination immediately after sample collection. Ammonia in the sample was reacted with hypochlorite and thymol to be converted into indothymol blue; then the formed indothymol blue was collected as an ion pair between indothymol blue and tetrabutylammonium ion on a Sep-Pak C18 cartridge.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!