Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Retrospective studies have shown that immunoassays measuring free light chains (FLC) in serum are useful for diagnosis and monitoring of multiple myeloma. This study prospectively evaluates the use of FLC assays and, for the first time, investigates the relationship between serum FLC concentrations and the presence and detectability of Bence Jones (BJ) proteins in the urine.
Patients And Methods: Three hundred seventy-eight paired samples of serum and urine were tested from 82 patients during the course of their disease. The sensitivities of serum FLC analysis and urine immunofixation electrophoresis (IFE) in detecting monoclonal FLC were compared. Serum FLC concentrations required for producing BJ proteins detected by IFE were determined.
Results: Abnormal FLC were present in 54% of serum samples compared with 25% by urine tests. In abnormal serum samples for kappa or lambda, the sensitivity of IFE to detect the respective BJ proteins in urine were 51% and 35% and the median serum FLC concentrations required to produce detectable BJ proteins were 113 and 278 mg/L. Renal excretions of monoclonal FLC increased with serum concentrations, but excretions significantly decreased at high serum concentrations combined with renal dysfunction.
Conclusion: Serum FLC assays are significantly more sensitive for detecting monoclonal FLC than urine IFE analysis. They also have the advantage of FLC quantification and are more reliable for monitoring disease course and response to treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1158/1078-0432.CCR-05-0486 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!