Background: Catheter ablation has significantly transformed the clinical management of atrial fibrillation (AF). The safety and efficacy of this procedure are not well understood in patients with pacemakers and defibrillators.

Objectives: The purpose of this study was to study the impact of radiofrequency catheter ablation of AF in patients with pacemakers and implantable cardiac defibrillators.

Methods: We studied 86 patients with pacemakers and defibrillators (group I) and a similar number of age- and gender-matched controls (group II) who underwent AF ablation between 1999 and 2004. Clinical and procedural variables were compared between the two groups. In group I, various generator and lead parameters were compared before and after the procedure. Resurgence of clinical AF after 2 months was considered recurrence.

Results: Both groups were similar with regard to age, gender, body mass index, and type of AF. Group I had a higher incidence of diabetes (17% vs 6%, P = .03), coronary artery disease (25% vs 13%, P = .05), less prolonged AF (31 +/- 21 vs 45 +/- 30 months, P <.001), lower left ventricular ejection fraction (49 +/- 13% vs 52 +/- 9%, P = .03), and left ventricular end-diastolic dimensions (4.97 +/- 0.81 vs 4.72 +/- 0.67, P = .03). No changes in the sensing and pacing thresholds, impedance of atrial and ventricular leads, or defibrillator coil impedance after AF ablation were observed in group I. Atrial lead dislodgment was seen in two patients. Transient abnormal but "expected" pulse generator behavior was seen in 25% of patients without permanent malfunction. Stroke (1% vs 1%, P = 1.000), pulmonary vein stenosis (2% vs 1%, P = .77), and AF recurrence rates at 12 months were similar between groups I and II, respectively (19% vs 21%, P = .73).

Conclusion: AF ablation is safe and efficacious in patients with pacemakers and defibrillators.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2005.09.010DOI Listing

Publication Analysis

Top Keywords

patients pacemakers
16
catheter ablation
12
safety efficacy
8
atrial fibrillation
8
pacemakers implantable
8
implantable cardiac
8
efficacy radiofrequency
4
radiofrequency energy
4
energy catheter
4
ablation
4

Similar Publications

Prognostic impact of one-year permanent pacemaker implantation after mitral valve surgery with the Cox-maze procedure.

Eur J Cardiothorac Surg

January 2025

Department of Thoracic and Cardiovascular Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea.

Objectives: This study aimed to evaluate the prognostic impact of permanent pacemaker (PPM) implantation within the first year after mitral valve (MV) surgery combined with the Cox-maze procedure, focusing on long-term outcomes, including overall mortality, infective endocarditis (IE), and ischaemic stroke.

Methods: We conducted a retrospective cohort study using data from the National Health Insurance Service (NHIS) in South Korea, identifying 10,127 patients who underwent MV surgery with the Cox-maze procedure between 2005 and 2020. Patients were classified into the PPM and non-PPM groups based on PPM implantation within one year postoperatively.

View Article and Find Full Text PDF

Epicardial Pacemaker Lead Related Cardiac Strangulation: The Importance of Early Recognition.

Pediatr Cardiol

January 2025

Cardiothoracic Department, Children's Health Ireland at Crumlin, Dublin, Ireland.

Lead strangulation is a dangerous complication of epicardial pacemaker insertion. This complication has been increasingly highlighted lately. Our institution has recently identified four cases over the past five years.

View Article and Find Full Text PDF

Background: Conduction disturbances are common after transcatheter aortic valve implantation (TAVI) and frequently require permanent pacemaker implantation (PPI). Data regarding its impact on mortality and morbidity are conflicting. This study aims to assess the impact of PPI before or within 30 days after TAVI on mortality and health-related Quality of Life (QoL) during the first year after TAVI.

View Article and Find Full Text PDF

Background: Guideline-recommended strategies to interrupt chronic anticoagulation with warfarin or direct oral anticoagulants (DOAC) during the perioperative period of cardiac implantable electronic device (CIED) surgery differ worldwide. There is uncertainty concerning the benefits and harms of interrupted and uninterrupted anticoagulation in patients undergoing CIED surgery.

Objectives: To assess the benefits and harms of interrupted anticoagulation (IAC) with either warfarin or DOAC in the perioperative period of CIED surgery versus uninterrupted anticoagulation (UAC), with or without heparin bridging, during an equivalent time frame, for CIED surgery.

View Article and Find Full Text PDF

Background: Cardioneuroablation (CNA) is a new approach to treat reflex syncope and functional bradyarrhytmias caused by autonomic imbalance. We report our experience using CNA.

Method: From September 2022 to July 2023, we took care of 21 patients (mean age 42 ± 21 years; 62% male) affected by reflex syncope or functional bradyarrhythmias.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!