A collection of DNA samples obtained from primary open-angle glaucoma (POAG) patients from St. Petersburg was analyzed for single-strand conformation polymorphism (SSCP) to reveal sequence variants in exon 3 of the myocilin gene (MYOC/TIGR) and in exons 4 and 5 of the optineurin gene (OPTN), where most of the mutations revealed worldwide are located. The Q368X mutation (c. 1102 C --> T) in exon 3 of MYOC/TIGR was detected in 1.2% (2/170) of the POAG patients from St. Petersburg, i.e., with the frequency close to that observed in other world populations. Three known polymorphisms in exon 3 of MYOC/TIGR, Y347Y (c. 1041 T --> C) (12.4%), T325T (c. 975 G --> A) (0.6%), and K398R (c. 1193 A --> G) (0.6%) were also detected. No statistically significant differences in frequencies of these polymorphisms were revealed between the POAG patient and control groups. The L41L polymorphism (c. 433 G --> A) in exon 4 of OPTN was detected in 2.9% of probands and in 1% of controls. The frequency of heterozygotes for the M98K polymorphism (c. 603 T --> A) in the OPTN exon 5 was statistically significantly higher (P = 0.036; Fisher's exact test) among the POAG patients (6.5%) than among the controls (1%). In the sample examined the E50K mutation, typical of the patients with pseudonormal intraocular pressure glaucoma, was not found.
Download full-text PDF |
Source |
---|
Jpn J Ophthalmol
January 2025
Department of Ophthalmology, Graduate of Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan.
Purpose: To assess the efficacy and safety of PreserFlo MicroShunt (PMS) combined with mitomycin C in patients with medically treated primary open-angle glaucoma (POAG).
Study Design: A retrospective observational study.
Methods: The study examined 83 eyes from 83 patients with medically treated glaucoma surgery naive POAG.
BMC Ophthalmol
January 2025
Department of Ophthalmology, Medical Faculty, University Hospital of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.
Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.
Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.
Am J Ophthalmol
January 2025
Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan; Center for Eye Policy and Innovation, University of Michigan, Ann Arbor, Michigan; Department of Health Management and Policy, University of Michigan School of Public Health, Ann Arbor, Michigan. Electronic address:
Purpose: A previously developed machine-learning approach with Kalman-filtering technology accurately predicted disease trajectory for patients with various glaucoma types and severities using clinical trials data. This study assesses performance of the KF approach with real-world data.
Design: Retrospective cohort study.
Prcis: Trabecular cutting minimally invasive glaucoma surgery like bent ab interno needle goniectomy (BANG) when performed in baseline aqueous angiography identified low aqueous humor outflow regions, results in greater success of intraocular pressure reduction.
Purpose: To study the efficacy of Bent Ab Interno Needle Goniectomy (BANG) in high versus low aqueous humor outflow (AHO) regions as determined by Aqueous Angiography(AA) in patients with primary open angle glaucoma (POAG).
Methods: A prospective, single-centre, pilot, randomized control trial recruited 30 eyes of 30 patients of POAG and visually significant cataract (45-80 y) and were randomised into two groups ("A": BANG performed in the high-flow regions and "B": BANG performed in the low-flow regions) of 15 each.
Ophthalmol Ther
January 2025
Rocky Vista University, Englewood, CO, USA.
Introduction: This retrospective, consecutive, real-world case series assessed the efficacy and safety of third-generation trabecular micro-bypass stent implantation (iStent infinite) with phacoemulsification in patients with mild-to-moderate primary open-angle glaucoma (POAG).
Methods: Patients underwent phacoemulsification combined with implantation of iStent infinite (containing three stents) by a single U.S.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!