The human visual system is adept at detecting and encoding statistical regularities in its spatiotemporal environment. Here, we report an unexpected failure of this ability in the context of perceiving inconsistencies in illumination distributions across a scene. Prior work with arrays of objects all having uniform reflectance has shown that one inconsistently illuminated target can 'pop out' among a field of consistently illuminated objects (eg Enns and Rensink, 1990 Science 247 721 723; Sun and Perona, 1997 Perception 26 519-529). In these studies, the luminance pattern of the odd target could be interpreted as arising from either an inconsistent illumination or inconsistent pigmentation of the target. Either cue might explain the rapid detection. In contrast, we find that once the geometrical regularity of the previous displays is removed, the visual system is remarkably insensitive to illumination inconsistencies, both in experimental stimuli and in altered images of real scenes. Whether the target is interpreted as oddly illuminated or oddly pigmented, it is very difficult to find if the only cue is deviation from the regularity of illumination or reflectance. Our results allow us to draw inferences about how the visual system encodes illumination distributions across scenes. Specifically, they suggest that the visual system does not verify the global consistency of locally derived estimates of illumination direction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1068/p5418 | DOI Listing |
Lasers Med Sci
January 2025
University of Zurich, Zurich, Switzerland.
The aim of this study was to compare the effectiveness of different types of low level laser treatment (LLLT) in reducing pain levels, changing oxygen saturation and bite force in patients with myofacial pain syndrome (MPS). 45 patients were randomly assigned to three groups: Group 1 (GRR laser, n = 15) received LLLT with Gallium-Aluminium-Arsenide (GaAlAs) diode laser with a wavelength of 904 nm and red laser with a wavelength of 650 nm over masseter muscle region. Group 2 (Nd: YAG laser, n = 15) were treated with Neodymium-doped Yttrium Aluminium Garnet laser with a wavelength of 1064 nm and the same protocol with Nd: YAG laser was performed in the Group 3 (placebo, n = 15) using sham device.
View Article and Find Full Text PDFEur J Phys Rehabil Med
January 2025
Preventive Medicine, Epidemiology and Public Health Area, Department of Biomedical and Diagnostic Sciences, University of Salamanca, Institute for Biomedical Research of Salamanca (IBSAL), Salamanca, Spain -
Background: Neck and back pain pathologies are currently the main cause of absenteeism from work in Spain and in the European Union, and represent a high socio-labor, economic and health cost for the Health Systems.
Aim: To assess the effectiveness of a Back School Program of a Spanish mutual insurance company (risk factors, pain and disability scales) in women workers with low back or neck pain.
Design: We combined a descriptive study of first-session data collected in the total sample and a prospective multicenter intervention study in those participants who completed the second and third check-up at 6 and 9 months.
Invest Ophthalmol Vis Sci
January 2025
Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
Purpose: This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.
Methods: In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders.
Int Conf Indoor Position Indoor Navig
October 2024
Computer Science and Engineering, University of California, Santa Cruz, Santa Cruz, United States.
In this paper, we present PALMS, an innovative indoor global localization and relocalization system for mobile smartphones that utilizes publicly available floor plans. Unlike most vision-based methods that require constant visual input, our system adopts a dynamic form of localization that considers a single instantaneous observation and odometry data. The core contribution of this work is the introduction of a particle filter initialization method that leverages the Certainly Empty Space (CES) constraint along with principal orientation matching.
View Article and Find Full Text PDFCerebrospinal fluid (CSF) dynamics, driven by sensory stimulation-induced neuronal activity, is crucial for maintaining homeostasis and clearing metabolic waste. However, it remains unclear whether such CSF flow is impaired in age-related neurodegenerative diseases of the visual system. This study addresses this gap by examining CSF flow during visual stimulation in glaucoma patients and healthy older adults using functional magnetic resonance imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!