Purpose: The Lanthony Desaturated Panel D-15 has been used to measure fine color discrimination for congenital and acquired color vision defects. This study investigated the test-retest reliability of the test using an intertest interval of approximately 1 month.
Methods: One hundred twenty-six color vision normals (mean age = 34.5 years) were administered several color vision tests, including the Lanthony Desaturated D-15. Normal color vision status was confirmed using the anomaloscope and HRR color plates. The color vision tests were readministered 3 to 6 weeks after initial testing. The results of the Lanthony test were expressed using the color confusion index of Bowman. The difference in Color Confusion Index (CCI) between the two administrations was calculated and used to determine the intraclass correlation coefficient.
Results: The overall mean CCI for the two administrations for these subjects was 1.11 +/- 0.136. The mean difference in CCI score between test administrations was -0.02 +/- 0.128. There was a strong correlation between the absolute value of the difference in CCI and the mean CCI for each subject (r = 0.51, p < 0.0001). The intraclass correlation coefficient was 0.56 (95% confidence interval, 0.43-0.67).
Conclusions: Although the Lanthony Desaturated D-15 test can be used to assess fine color discrimination, there is considerable within-subject variability in test results. The intraclass correlation coefficient is less than that recommended for use in clinical testing or research. Clinicians should consider at least three administrations of the test at each sitting to ensure precision and we recommend taking the mean of those three tests.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.opx.0000192351.63069.4a | DOI Listing |
Am Fam Physician
January 2025
Western University Schulich School of Medicine and Dentistry, London, Ontario, Canada.
Vision loss affects more than 7 million Americans and impacts quality of life, independence, social functioning, and overall health. Common and dangerous conditions causing sudden vision loss include acute angle-closure glaucoma, retinal detachment, retinal artery occlusion, giant cell arteritis, and optic neuritis. Acute angle-closure glaucoma features ocular pain, headache, and nausea; treatment includes pilocarpine eye drops, oral or intravenous acetazolamide, and intravenous mannitol.
View Article and Find Full Text PDFEye (Lond)
January 2025
Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.
Purpose: To determine how Hardy-Rand-Rittler (HRR) colour vision testing correlates with visual functional and structural assessments in Cone and Cone-Rod Dystrophy.
Methods: Thirty-four Cone and 69 Cone-Rod Dystrophy patients diagnosed by electroretinography (ERG) at the Save Sight Institute in Sydney were included in a retrospective analysis. Each patient's HRR colour vision test scores were compared with markers of cone and rod system function including visual acuity (VA), ERG responses, changes on Spectral Domain Optical Coherence Tomography (OCT) and Fundus Autofluorescence.
Biotechnol Bioeng
January 2025
State Key Laboratory of Bioreactor Engineering, Qingdao Innovation Institute of East China University of Science and Technology, East China University of Science and Technology, Shanghai, China.
High-performance strain and corresponding fermentation process are essential for achieving efficient biomanufacturing. However, conventional offline detection methods for products are cumbersome and less stable, hindering the "Test" module in the operation of "Design-Build-Test-Learn" cycle for strain screening and fermentation process optimization. This study proposed and validated an innovative research paradigm combining computer vision with deep learning to facilitate efficient strain selection and effective fermentation process optimization.
View Article and Find Full Text PDFActa Psychol (Amst)
January 2025
Faculty of Psychology, University of Vienna, Vienna, Austria; Vienna Cognitive Science Hub, Vienna, Austria.
Colour plays an important role in the sighted world, not only by guiding and warning, but also by helping to make decisions, form opinions, and influence emotional landscape. While not everyone has direct access to this information, even people without colour vision (i.e.
View Article and Find Full Text PDFBrain Cogn
January 2025
School of Information Science and Technology, Yunnan Normal University, Kunming, China; Yuxi Key Laboratory of Mental Health Examination, Yuxi 653100, Yunnan, China; Engineering Research Center of Computer Vision and Intelligent Control Technology, Department of Education of Yunnan Province, Kunming, China. Electronic address:
Differences in the brain sensitivity to color responses may cause significant differences in the latency and amplitude of the electroencephalographic (EEG) component. This paper investigated the electroencephalography features of binocular color fusion and binocular color rivalry when watching stereoscopic three-dimensional (3D) displays. EEG experiments were conducted on a conventional 3D display platform.