Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

J Anal Toxicol

Israel Poison Information Center, Rambam Medical Center, Faculty of Medicine, Technion, Haifa, Israel.

Published: January 2006

A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/29.8.794DOI Listing

Publication Analysis

Top Keywords

urine samples
12
urine
9
methylene chloride
8
sampling protocol
8
mecl2 analysis
8
exposed workers
8
sealing hsv
8
mecl2 urine
8
collection urine
8
hsv
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!