Objectives: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones.
Study Design: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation.
Animal Population: Twelve pairs of adult equine cadaveric MC3 bones.
Methods: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05.
Results: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation.
Conclusion: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing.
Clinical Relevance: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1532-950X.2005.00092.x | DOI Listing |
Storing complex correlated memories is significantly more efficient when memories are recoded to obtain compressed representations. Previous work has shown that compression can be implemented in a simple neural circuit, which can be described as a sparse autoencoder. The activity of the encoding units in these models recapitulates the activity of hippocampal neurons recorded in multiple experiments.
View Article and Find Full Text PDFSoft Matter
January 2025
James Franck Institute and Department of Physics, The University of Chicago, Chicago, Illinois 60637, USA.
We measure the response of open-cell polyurethane foams filled with a dense suspension of fumed silica particles in polyethylene glycol at compression speeds spanning several orders of magnitude. The gradual compressive stress increase of the composite material indicates the existence of shear rate gradients in the interstitial suspension caused by wide distributions in pore sizes in the disordered foam network. The energy dissipated during compression scales with an effective internal shear rate, allowing for the collapse of three data sets for different pore-size foams.
View Article and Find Full Text PDFSci Rep
January 2025
Jiangsu Aegis Haizhu Machinery Co., Ltd, Huaian, 223100, People's Republic of China.
To further investigate the properties of Incoloy825/P110 bimetallic composite seamless pipes, thermal deformation analysis was conducted on their billets. The thermal deformation and dynamic recrystallization (DRX) behavior of Incoloy825/P110 bimetallic composite materials were studied through hot compression tests at deformation temperatures (850-1150 °C) and strain rates (0.01-10 s).
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:
Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.
View Article and Find Full Text PDFHand Surg Rehabil
January 2025
Centre Hospitalier Régional Universitaire de Nîmes, Department of Orthopaedic Surgery, Nîmes, France.
Dynamic compression of the median nerve under the lacertus fibrosus at the elbow causes pain and weakness. It is a frequently overlooked pathology and a cause of failed recovery after carpal tunnel release. The purpose was to present a technical note on minimally invasive ultrasound-guided lacertus syndrome surgical treatment under WALANT.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!