We simulated refraction contrast imaging in overlapping objects using the ray tracing method. The easiest case, in which two columnar objects (blood vessels) with a density of 1.0 [g/cm3], run at right angles in air, was calculated. For absorption, we performed simulation using the Snell law adapted to the object's boundary. A pair of bright and dark spot results from the interference of refracted X-rays where the blood vessels crossed. This has the possibility of increasing the visibility of the image.

Download full-text PDF

Source

Publication Analysis

Top Keywords

ray tracing
8
overlapping objects
8
refraction contrast
8
contrast imaging
8
blood vessels
8
tracing analysis
4
analysis overlapping
4
objects refraction
4
imaging simulated
4
simulated refraction
4

Similar Publications

Ways to Measure Metals: From ICP-MS to XRF.

Curr Environ Health Rep

January 2025

School of Health Sciences, Purdue University, West-Lafayette, IN, 47906, USA.

Purpose Of Review: This review explores the use of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and X-ray Fluorescence (XRF) for quantifying metals and metalloids in biological matrices such as hair, nails, blood, bone, and tissue. It provides a comprehensive overview of these methodologies, detailing their technological limitations, application scopes, and practical considerations for selection in both laboratory and field settings. By examining traditional and novel aspects of each method, this review aims to guide researchers and clinical practitioners in choosing the most suitable analytical tool based on their specific needs for sensitivity, precision, speed, and sample preparation.

View Article and Find Full Text PDF

Introduction: Zinc, an essential trace element, plays an important role in various cellular processes, and zinc deficiency is common in patients undergoing hemodialysis. Zinc has been shown to stimulate osteoblastic bone formation and mineralization and inhibit osteoclastic bone resorption. Although osteoporosis is highly prevalent among patients undergoing hemodialysis, the utility of areal bone mineral density (aBMD) measured using dual-energy X-ray absorptiometry (DXA) is limited because DXA cannot reveal bone microarchitectural alterations.

View Article and Find Full Text PDF

Underwater acoustic transducers need to expand the coverage of acoustic signals as much as possible in most ocean explorations, and the directivity indicators of transducers are difficult to change after the device is packaged, which makes the emergence angle of the underwater acoustic transducer limited in special operating environments, such as polar regions, submarine volcanoes, and cold springs. Taking advantage of the refractive characteristics of sound waves propagating in different media, the directivity indicators can be controlled by installing an acoustic lens outside the underwater acoustic transducer. To increase the detection range of an underwater acoustic transducer in a specific marine environment, a curvature-determining method for the diverging acoustic lens of an underwater acoustic transducer is proposed based on the acoustic ray tracing theory.

View Article and Find Full Text PDF

To improve maneuverability, the focus of photoelectric theodolites is on reducing the weight of the primary mirror and enhancing its optical performance. This study uses MOAT and Sobol methods to identify key parameters that affect design. Using the high-sensitivity part as the optimization domain, six optimization results were obtained based on the multi-objective SIMP topology optimization method and synthesized into a compromise optimization structure.

View Article and Find Full Text PDF

Rhabdophane, CePO∙HO, nanoparticles were prepared by mechanochemical synthesis with different durations and thoroughly characterized by various characterization techniques. X-ray diffraction analysis showed that the optimal synthesis duration was 15 min, since, in this case, pure rhabdophane is obtained, without traces of contamination by the vessel material. The size of the obtained nanoparticles, as determined from high-resolution transmission electron microscopy images, was around 5 nm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!