Cardiac arrhythmias are among the leading causes of morbidity and mortality of transfusion-dependent, iron-overloaded beta-thalassemia patients. Routine screening with Holter electrocardiogram has been recommended; however, infrequent electrocardiographic changes limit its clinical usefulness. The purpose of this study was to determine the diagnostic yield of Holter electrocardiogram monitoring and its correlation with patient symptoms and disease status. A retrospective analysis was performed on 27 transfusion-dependent thalassemia patients who underwent cardiac questionnaire and Holter screening yearly, in addition to echocardiogram and quantitative iron-level determination. Four patients had clinically significant arrhythmias detected on Holter screening, while 2 patients developed severe cardiac complications secondary to arrhythmias within 1 year of follow-up of normal Holter screening. Early detection of cardiac events among transfusion-dependent thalassemia patients with Holter electrocardiography is not clinically effective. Other screening modalities, including the transtelephonic event recorder, should be evaluated in arrhythmia surveillance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1196/annals.1345.064 | DOI Listing |
Arq Bras Cardiol
January 2025
Cardiovascular Medicine Department, Faculty of Medicine, Tanta University, Tanta - Egito.
Background: There is still a significant population of patients with embolic stroke of Undetermined Source (ESUS) whose specific attributable cause of the stroke remains unknown.
Objectives: Our research aimed to assess clinical, electrocardiogram, laboratory, and echocardiographic parameters that may predict the propensity of paroxysmal atrial fibrillation (PAF).
Methods: We enrolled seventy-five ESUS patients who were in sinus rhythm at the time of stroke diagnosis to undergo in-hospital 7-day Holter monitoring, testing for Pro-BNP, and a standard echocardiographic examination.
Sleep Breath
January 2025
Department of Cardiac and Vascular Diseases, Jagiellonian University Medical College, John Paul II Hospital, Prądnicka 80, Kraków, 31-202, Poland.
Background: Obstructive sleep apnoea (OSA) may lead to heart rhythm abnormalities including bradycardia. Our aim was to ascertain clinical and echocardiographic parameters in patients with OSA in whom severe bradycardia was detected in an outpatient setting, as well as to evaluate the efficacy of CPAP therapy on heart rate normalization at the early stages of treatment.
Methods: Fifteen patients mild, moderate or severe OSA and concomitant bradycardia were enrolled.
Digit Health
January 2025
Department of Cardiology, Peking University First Hospital, Beijing, China.
Background: Wearables satisfactorily detect atrial fibrillation (AF) longer than 1 hour. Our study aims to evaluate smartwatch performances for long-term AF monitoring, including AF with short durations.
Methods: This prospective study enrolled AF patients from 2020 to 2023.
This analysis assessed the relationship between the plasma concentrations of loperamide and its N-desmethyl loperamide meta- bolite (M1) and the potential QT interval prolongation at therapeutic and supratherapeutic doses. The exposure-response analysis was performed using the data from healthy adults participating in a randomized, double-blind, single-dose, four-way (placebo; loperamide 8 mg [therapeutic]; loperamide 48 mg [supratherapeutic]; moxifloxacin 400 mg [positive control]) crossover study. The electrocardiographic measurements extracted from 12-lead digital Holter recordings were time-matched to pharmacokinetic sampling of loperamide/M1.
View Article and Find Full Text PDFBiomedicines
January 2025
Department of Emergency Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.
Background/objectives: Autoimmune inflammation enhances the electrical instability of the atrial myocardium in patients with systemic sclerosis (SSc); thus, atrial arrhythmia risk is increased, which might be predicted by evaluating the P wave interval and dispersion of a 12-lead surface electrocardiogram (ECG).
Methods: We examined 26 SSc patients and 36 healthy controls and measured the P wave interval and P wave dispersion of the 12-lead surface ECG in each patient. Furthermore, echocardiography and 24-h Holter ECG were performed and levels of inflammatory laboratory parameters, including serum progranulin (PGRN), sVCAM-1, sICAM-1, leptin and C-reactive protein (CRP), were determined.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!