Sperm whales (Physeter macrocephalus) produce multipulsed clicks with their hypertrophied nasal complex. The currently accepted view of the sound generation process is based on the click structure measured directly in front of, or behind, the whale where regular interpulse intervals (IPIs) are found between successive pulses in the click. Most sperm whales, however, are recorded with the whale in an unknown orientation with respect to the hydrophone where the multipulse structure and the IPI do not conform to a regular pulse pattern. By combining far-field recordings of usual clicks with acoustic and orientation information measured by a tag on the clicking whale, we analyzed clicks from known aspects to the whale. We show that a geometric model based on the bent horn theory for sound production can explain the varying off-axis multipulse structure. Some of the sound energy that is reflected off the frontal sac radiates directly into the water creating an intermediate pulse p1/2 seen in off-axis recordings. The powerful p1 sonar pulse exits the front of the junk as predicted by the bent-horn model, showing that the junk of the sperm whale nasal complex is both anatomically and functionally homologous to the melon of smaller toothed whales.

Download full-text PDF

Source
http://dx.doi.org/10.1121/1.2082707DOI Listing

Publication Analysis

Top Keywords

multipulse structure
12
sperm whale
8
usual clicks
8
sound production
8
sperm whales
8
nasal complex
8
whale
6
off-axis effects
4
effects multipulse
4
structure
4

Similar Publications

We demonstrate a 2.08 µm all-polarization-maintaining (PM) holmium-doped fiber oscillator using a hybrid mode-locking technique with nonlinear polarization evolution (NPE) and a semiconductor saturable absorber mirror (SESAM). This oscillator features a linear structure with dual output ports.

View Article and Find Full Text PDF

Although no optically visible damage is produced in the fused silica under laser irradiation below its laser-induced damage threshold (LIDT), defect proliferation may occur due to the evolution of its internal atomic structure. The escalation in defect content leads to heightened absorption, and resulting in the degradation of the optical performance of the optics. In recent decades, there have been a lot of experimental studies on laser-induced damage and laser conditioning, but there is still a great lack of in-depth understanding and theoretical analysis of the evolution process of point defects in fused silica.

View Article and Find Full Text PDF

Molecular signaling predicts corticospinal axon growth state and muscle response plasticity induced by neuromodulation.

Proc Natl Acad Sci U S A

November 2024

Department of Molecular, Cellular, and Biomedical Sciences, Center for Discovery and Innovation, City University of New York School of Medicine, New York, NY 10031.

Article Synopsis
  • Electrical motor cortex stimulation can enhance motor function and support structural changes in the corticospinal system after injuries, with a focus on finding molecular biomarkers for this plasticity.
  • Two neuromodulation techniques were tested: repetitive multipulse stimulation (rMPS) and intermittent theta burst stimulation (iTBS), revealing that only iTBS effectively promoted corticospinal tract sprouting after short-term stimulation.
  • Key molecular changes, including mTOR activation and PTEN deactivation, were associated with significant axon growth, indicating that iTBS may be the better option for recovery after spinal cord injuries due to its effects on both structural and physiological plasticity.
View Article and Find Full Text PDF

Ultra-high dose rate FLASH radiotherapy, a promising cancer treatment approach, offers the potential to reduce healthy tissue damage during radiotherapy. As the mechanisms underlying this process remain unknown, several hypotheses have been proposed, including the altered production of radio-induced species under ultra-high dose rate (UHDR) conditions. This study explores realistic irradiation scenarios with various dose-per-pulse and investigates the role of pulse temporal structure.

View Article and Find Full Text PDF

To solve the problem of the large size of traditional industrial frequency phase-shift transformers and the harmonic distortion of multi-pulse wave rectifier systems, this paper proposes a three-stage shunt zigzag power electronic phase-shift transformer based on a double-tap multi-pulse wave rectifier, which combines the power factor correction (PFC) converter with the voltage-type SPWM inverter circuit to form a power electronic converter to realize the frequency boost and power factor correction. Through AC-DC-AC conversion, the frequency of the three-phase AC input voltage is increased, the number of core and coil turns in the transformer is reduced to reduce the size of the phase-shifter transformer, a zigzag structure of the phase-shifter transformer is used to solve the unbalanced distribution of current between the diode bridges, and a passive harmonic suppression method on the DC side is used to generate a loop current by using a group of single-phase rectifier bridges to regulate the input line current of the phase-shifter transformer. The phase-shifted voltage is input into two three-phase diode rectifier bridges to rectify and supply power to the load.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!