The repeated bout effect (RBE) is a phenomenon characterized by less delayed onset muscle soreness (DOMS) and torque deficit after the second of 2 separate eccentric exercise bouts. Previous investigators have reported that shifting of optimum angle after an initial bout of eccentric exercise mediates the RBE. We hypothesized that an RBE for elbow extensor exercise occurs after an initial bout performed at long (starting position of 50 degrees to an end position of 130 degrees) but not short (starting position of 0 degrees to an end position of 80 degrees) muscle length because strain at long length evokes a shifting of the optimum angle to a longer length. Untrained women performed an initial bout at either long or short length (n = 9 per group) followed 1 week later by a repeated bout (RB) through the full ROM (0-130 degrees). Extensor torque and optimum angle was evaluated before, immediately after, and 2 days after each bout. A mechanical transducer depressed on the triceps brachii quantified DOMS. Torque deficits were 3% and 7% after exercise at short vs. long length, respectively. Two days after the RB, torque deficit was 8% and 1% for those previously exercising at short vs. long length (group x bout, p < 0.05). Greater DOMS (N) was observed after exercise at long (16 +/- 3) vs. short (23 +/- 2) length; whereas greater DOMS occurred for the short-length (17 +/- 2) vs. long (26 +/- 3) group after the RB (group x bout, p < 0.05). Optimum angle shifted to a longer length after exercise at long (+10 +/- 4 degrees) vs. short (+1 +/- 3 degrees) length (group x bout, p < 0.05). After the RB, those exercising previously at short length experienced a shift of +15 +/- 4 degrees (main effect, p < 0.05). The findings of this study indicate that the repetitive strain at long but not short muscle length evokes both immediate and sustained shifts in optimum angle to longer lengths, and that this shifting mediates (r(2) = 0.71) the RBE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/r-16254.1 | DOI Listing |
Sci Rep
December 2024
School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China.
Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.
View Article and Find Full Text PDFSci Rep
December 2024
State Key Laboratory of Shield Machine and Boring Technology, Zhengzhou, 450001, China.
This paper presents an analytical solution derived with force method for the internal forces in the ring lining of maglev train tunnels, which are typically in a circular section and shallowly buried with low vacuum air pressure in the lining. The model incorporates the vacuum pressure induced by the differences in air pressures outside and inside the lining, and the vacuum pressure is assumed to be the active load exerting to the outside of the lining. The model assumes the vertical overburden acting on the lining is proportional to the soil depth at every particular point along the tunnel lining circumference.
View Article and Find Full Text PDFJ Orthop Surg Res
December 2024
Department of Orthopeadics, the First Medical Centre, Chinese PLA General Hospital, Beijing, China.
Background: This study aimed to report the mid-term functional outcomes of total hip arthroplasty (THA) for the treatment of advanced hip involvement in ankylosing spondylitis (AS) and identify the factors associated with poor hip flexion range of motion (ROM) after THA in patients with AS.
Methods: We retrospectively investigated the mid-term functional outcomes in 313 AS patients (538 hips) who underwent primary THA from 2012 to 2017, with a mean follow-up of 7 years (range, 4-9 years). Postoperative functional outcomes were assessed by hip flexion ROM, Harris hip score (HHS), and the Western Ontario and McMaster Universities Arthritis Index (WOMAC).
J Chem Phys
December 2024
Department of Chemistry, Ohio State University, 100 West 18th Avenue, Columbus, Ohio 43210, USA.
A simplified theoretical description of multiple-quantum excitation and mixing for nuclear magnetic resonance of half-integer quadrupolar nuclei is presented. The approach recasts the multiple-quantum nutation behavior in terms of reduced excitation and mixing curves through a scaling of the first-order offset frequency by the quadrupolar coupling constant. The two-dimensional correlation of the static first-order anisotropic line shape to the second-order anisotropic magic-angle-spinning (MAS) line shape is utilized to transform the three-dimensional integral over the three Euler angles into a single integral over the dimensionless first-order offset parameter.
View Article and Find Full Text PDFInt J Pediatr Otorhinolaryngol
December 2024
Autolab Technologies Pvt. Ltd., Lalitpur, Nepal.
Introduction: Intranasal steroids are effective in managing adenoid hypertrophy in children, but the evidence regarding technique of use for optimal results is lacking.
Methods: CFD analysis, with discrete phase modelling was done to simulate nasal spray in nasal cavity and drug delivery in the region of adenoids. The findings were validated using a 3D model designed from CT scan of the same region.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!