Purpose: To evaluate the safety and efficacy of modified intracorneal ring segment implantation (INTACS) in the management of moderate and advanced keratoconus (KCN).
Methods: A modified procedure of intracorneal ring segment (INTACS) implantation was performed in eyes with moderate to advanced keratoconus that were intolerant to contact lens or spectacle correction. The main outcome measures were uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), refraction, and keratometry. The preoperative values were compared with the values 6 and 12 months postoperatively.
Results: Implantation was performed on 20 eyes of 15 patients; 9 were female and 6 were male. The mean age was 30.2 years (SD +/- 5.44; range, 23-40). At the 6-month follow-up, UCVA improved from 20/154 (SD +/- 0.11) preoperatively to 20/28 (SD +/- 0.21) postoperatively (P < 0.05); BCSVA improved from 20/37 (SD +/- 0.21) preoperatively to 20/22 (SD +/- 0.13) postoperatively (P < 0.05). Spherical refractive error improved from -3.38 D (SD +/- 3.12) to -1.15 D (SD +/- 1.84); cylindrical refractive error improved from -3.75 (SD +/- 2.04) preoperatively to -1.21 (SD +/- 0.84) postoperatively (P < 0.05); average keratometry decreased from 49.50 D (SD +/- 1.64) preoperatively to 46.35 D (SD +/- 1.50) postoperatively. The changes remained stable to the 12-month follow-up. There was 1 case of anterior chamber perforation. There were 6 eyes that had ring exposure secondary to corneal thinning over the implants 3-6 months postoperatively, and a dense corneal infiltrate developed in 1 patient at 7 months postoperatively.
Conclusions: The procedure appears to be effective in improving UCVA and BSCVA of patients with clinical keratoconus. In our small study group, however, there were significant (6/20) postoperative problems with regards to thinning and ring exposure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.ico.0000167883.63266.60 | DOI Listing |
PLoS One
December 2024
ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Background: The cornea plays a role in the refractive power of the eye, and when its natural curvature and thickness are compromised by diseases such as keratoconus or high myopia, this results in loss of visual acuity. Intracorneal rings (ICRs) were developed as a treatment option to restore the natural corneal curvature by implanting rings into tunnels cut within the corneal stroma. However, selecting and placing the appropriate ring can be difficult, and predicting refractive outcomes is challenging.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
December 2024
Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of São Paulo, São Paulo, Brazil.
Purpose: This is a case report of a 31-year-old male patient presenting progressive and markedly asymmetric keratoconus treated with sequential intracorneal ring segment (ICRS) implantation followed by accelerated corneal cross-linking (CXL).
Observations: The follow-up after the last procedure revealed a thin, opacified cornea with an unexpected massive flattening of up to 20.3 D.
Cureus
September 2024
Ophthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND.
Keratoconus is a progressive corneal disorder characterized by thinning and conical protrusion, leading to visual impairment that often necessitates advanced treatment strategies. Traditional management options, including corrective lenses, corneal cross-linking (CXL), and surgical interventions such as corneal transplants and intracorneal ring segments (ICRS), address symptoms but have limitations, especially in progressive or advanced cases. Recent advancements in corneal stromal regeneration offer promising alternatives for enhancing vision restoration and halting disease progression.
View Article and Find Full Text PDFJ Clin Med
September 2024
Department of Cornea, Dr. Agarwal's Eye Hospital and Eye Research Centre, Chennai 600018, India.
This pilot ex vivo study and first clinical experience in Italy evaluate the impact of using pre-implantation crosslinking on all-femtosecond laser-cut corneal allogenic intracorneal ring segments (AFXL CAIRSs). Six human donor eye-bank corneas were used for this preclinical ex vivo human study. Three donor (D) corneas were used for AFXL CAIRSs.
View Article and Find Full Text PDFMed J Armed Forces India
December 2022
Consultant (Ophthalmology) & Brig I/C Adm, Command Hospital (Eastern Command), Kolkata, India.
Background: To study the correlation of different variables of Vogt striae to other attributes of keratoconus and to suggest a new grading system for Vogt striae to exactly represent the configuration and extent in each individual keratoconic cornea.
Methods: The study was an observational and data review study. A total of 386 eyes of 207 keratoconus patients were screened from February 2016 to August 2018.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!