Objective: To establish an optimized method to detect 8-OH-dG after DNA oxidation damage by capillary zone electrophoresis.
Methods: HepG2 cell was used as target cell and conditions for the separation and detection were obtained by studying the influence of pH of the running buffer, temperature, running voltage on the separation. 0 and 15 mmol/L H2O2 were added into two groups of HepG2 cells (5 x 10(7)) respectively for 24h. DNA was extracted by saturated salting out method to avoid the formation of additional 8-OH-dG by the method of phenol/chloroform extraction. DNA samples were digested to free nucleotides by incubation overnight at 37 degrees C with a mixture of DNase I, snake venom phosphoatase and alkaline phosphate. Proteins were removed and the supernatant was neutralized and then extracted with diethyl ether. The residue was evaporated to dryness and reconstituted and then analyzed under the optimized conditions by capillary zone electrophoresis.
Results: The optimized conditions were: uncoated silica capillary (47 cm x 50 microm i.d.), 20 mmol/L borate buffer (pH 9.5), 25 degrees C, 25kV. The sample was injected by hydrostatic method for 20s. In either of H2O2-treated group and H2O2-untreated group, the peak of 8-OH-dG was detected. The 8-OH-dG content of H2O2-untreated DNA increased.
Conclusion: The method is convenient, rapid, sensitive and cheap and safe. It provides an experimental platform to the application of 8-OH-dG in the biological monitoring of population.
Download full-text PDF |
Source |
---|
Scand J Clin Lab Invest
January 2025
Department of Medical Biochemistry, Health Science University, Istanbul Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
This study assessed the reliability of Roche Accu-Chek Inform II glucometers in a real-world setting. A retrospective analysis was conducted on 6,695 paired results. Capillary samples were tested using Roche Accu-Chek Inform II glucometers, while venous samples were analyzed using Roche Cobas c503/702 analyzers.
View Article and Find Full Text PDFViruses
December 2024
Department of Infectious Diseases and Hepatology, Medical University of Białystok, 15-540 Białystok, Poland.
The SARS-CoV-2 infection manifests with diverse clinical manifestations, with severity potentially influenced by the viral variant. COVID-19 has also been shown to impact ocular microcirculation in some patients, but whether this effect varies by viral lineage remains unclear. This prospective study compared clinical features and ocular parameters assessed via optical coherence tomography angiography (OCTA) in patients recovering from SARS-CoV-2 infections during the dominance of two distinctive viral lineages, Alpha (B.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
January 2025
Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, United States.
Purpose: To assess the preferential sites of retinal capillary occlusion at the parafovea in patients with sickle cell disease (SCD) using optical coherence tomography angiography (OCT-A).
Methods: OCT-A scans from 107 patients with SCD and 51 race-matched unaffected controls were obtained using a commercial spectral domain-OCT system. At least eight sequential 3 × 3 mm scans centered at the fovea were acquired and averaged for image analysis.
Diabetes Obes Metab
January 2025
School of Medicine, Western Sydney University, Campbelltown, New South Wales, Australia.
Aims: Physiological changes during pregnancy can infuence the performance of blood glucose meters. This study aimed to evaluate the analytical and clinical accuracy of glucose meters in pregnant women with hyperglycaemia.
Materials And Methods: Glucose was measured by four commonly used meters among consecutive women with diabetes in pregnancy.
Curr Issues Mol Biol
January 2025
Institute of Experimental Medicine, Almazov National Medical Research Centre, 15B Parkhomenko Street, 194021 Saint Petersburg, Russia.
Myocardial ischemia-reperfusion injury increases myocardial microvascular permeability, leading to enhanced microvascular filtration and interstitial fluid accumulation that is associated with greater microvascular obstruction and inadequate myocardial perfusion. A burst of reactive oxygen species and inflammatory mediators during reperfusion causes myosin light chain kinase (MLCK)-dependent endothelial hyperpermeability, which is considered a preventable cause of reperfusion injury. In the present study, a single intravenous injection of MLCK peptide inhibitor PIK7 (2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!