Aluminum foreign bodies: do they show up on x-ray?

Emerg Radiol

Department of Emergency Medicine, Brown Medical School, Providence, RI 02903, USA.

Published: December 2005

The objective of this study is to evaluate the utility of radiographs in the detection of aluminum foreign bodies (FB). Aluminum can tabs were placed at the upper esophagus/posterior pharyngeal area in ten randomly selected cadavers. Anterior-posterior (AP) and lateral (LAT) radiographies were performed before and after placement. Twenty sets of randomly ordered radiographs were assessed by two blinded radiologists for the presence of radio-opaque FB. For any positive reading on an AP or a LAT radiograph, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for radiologist A were 80, 90, 89, and 82%, respectively, and for radiologist B were 90, 100, 100, and 91%, respectively. These values were also calculated using only AP and LAT views. Aluminum FB can often be visualized on radiographs. The sensitivity of this method, however, is not adequate to completely rule out their presence. Additional testing in these cases is warranted. Conversely, a high PPV suggests that therapy based on this finding alone is a logical choice.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10140-005-0437-9DOI Listing

Publication Analysis

Top Keywords

aluminum foreign
8
foreign bodies
8
aluminum
4
bodies x-ray?
4
x-ray? objective
4
objective study
4
study evaluate
4
evaluate utility
4
utility radiographs
4
radiographs detection
4

Similar Publications

Within the scope of this study, a polymer-based optical sensor that can polymerize under UV radiation and produce fluorescence when suitable functional monomers and crosslinkers were prepared for aluminum determination in yogurt, soybean flour, and meat samples. Parameters such as operating range, pH, sensitivity, selectivity, determination limit, and foreign ion effect were thoroughly investigated to validate the developed method and characterize this polymer-based membrane. The designed sensor has wavelengths of 322 nm for fluorescence excitation and 356 nm for emission, respectively.

View Article and Find Full Text PDF

Evaluating export vulnerability through import demand elasticity in carbon border adjustment contexts: a focus on Türkiye.

Environ Sci Pollut Res Int

January 2025

Department of International Trade and Business, Faculty of Economics and Administrative Sciences, Inonu University, 44000, Malatya, Turkey.

Import demand elasticity (IDE) is a critical metric often employed to guide government decisions regarding tariffs and non-tariff barriers, ensuring that foreign trade remains uninterrupted while optimizing tax revenues. This study, however, leverages IDE to assess the impact of the carbon border adjustment mechanism (CBAM) on Türkiye's decarbonization process. Specifically, the research analyzed the total export quantities and unit prices of four product groups-cement, fertilizers, and inorganic chemicals, steel and iron, and aluminum-exported from Türkiye to the European Union-27 countries under the CBAM framework between 2002 and 2021.

View Article and Find Full Text PDF

Introduction: (Arabica coffee) is an important cash crop in Yunnan, China. Ongoing climate change has made coffee production more difficult to sustain, posing challenges for the region's coffee industry. Predictions of the distribution of potentially suitable habitats for Arabica coffee in Yunnan could provide a theoretical basis for the cultivation and rational management of this species.

View Article and Find Full Text PDF

Objective: To report a case of oral tongue entrapment due to a metal water bottle and review clinical considerations for managing this rare pathology.

Study Design: Case report and literature review.

Setting: Tertiary care hospital.

View Article and Find Full Text PDF

In this study, the cooling effect below ambient air temperature, heat dissipation properties and heating energy efficacy of a superomniphobic self-cleaning (SSC) highly emissive (HE) coating were systematically investigated. Except at midday, the SSC-HE coating with an extremely high solar reflectance of 0.985 showed a better cooling effect than a 10-cm-thick polyurethane insulation layer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!