Prehension stability: experiments with expanding and contracting handle.

J Neurophysiol

Department of Kinesiology, The Pennsylvania State University, University Park, PA 16802, USA.

Published: April 2006

We studied adjustments in digit forces and moments during holding a vertically oriented handle under slow, externally imposed changes in the width of the grasp. Subjects (n = 8) grasped a customized motorized handle with five digits and held it statically in the air. The handle width either increased (expanded) or decreased (contracted) at a rate of 1.0, 1.5, or 2.0 mm/s, while the subjects were asked to ignore the handle width changes, and their attention was distracted. External torques of 0.0, 0.25, and 0.5 Nm were applied to the handle in two directions. Forces and moments at the digit tips were measured with six-component sensors. The analysis was performed at the virtual finger (VF) and individual finger (IF) levels (VF is an imagined finger that produces the same wrench, i.e., the force and moment, as several fingers combined). In all the tasks, the normal VF and thumb forces increased with the handle expansion and decreased with the handle contraction. Similar behavior was seen for the thumb tangential force. In contrast, the VF tangential force decreased with the handle expansion and increased with the handle contraction. The changes in the tangential forces assisted the perturbations in the tasks requiring exertion of the supination moments and annulled the perturbation in the pronation effort tasks. In the former tasks, the equilibrium was maintained by the changes of the moments of normal forces, whereas in the latter tasks, the equilibrium was maintained by the changes of the moments of the tangential forces. Analysis at the IF level has shown that the resultant force and moment exerted on the object could arise from dissimilar adjustments of individual fingers to the same handle width change. The complex adjustments of digit forces to handle width change may be viewed as coming from two sources. First, there are local spring-like adjustments of individual digit forces and moments caused by both mechanical properties of the digits and the action of spinal reflexes. These stiffness-like reactions mainly assist in perturbing the rotational equilibrium of the object rather than in maintaining it. Second, there are tilt-preventing adjustments defined by the common task constraints that unite the digits into a task-specific synergy. The "virtual springs theory" developed in robotics literature is insufficient for describing the phenomena observed in human grasping.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2827039PMC
http://dx.doi.org/10.1152/jn.00839.2005DOI Listing

Publication Analysis

Top Keywords

handle width
16
handle
12
digit forces
12
forces moments
12
adjustments digit
8
forces
8
force moment
8
increased handle
8
handle expansion
8
decreased handle
8

Similar Publications

Aims And Background: The golden proportion is based on the premise that there is a link between natural beauty and mathematics. The study aimed to analyze the mesiodistal width of maxillary anterior teeth in primary and permanent dentition to determine whether a golden proportion exists among them.

Materials And Methods: Sixty subjects were randomly selected in accordance with inclusion and exclusion criteria.

View Article and Find Full Text PDF

Background: Myogenic factor 6 (Myf6) plays an important role in muscle growth and differentiation. In aquatic animals and livestock, Myf6 contributes to improving meat quality and strengthening the accumulation of muscle flavor substances. However, studies on Myf6 gene polymorphisms in crustaceans have not been reported.

View Article and Find Full Text PDF

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

Background: Timely diagnosis of heart failure (HF) in patients with a systemic right ventricle (sRV) is difficult but important since clinical deterioration is fast once HF develops. We aimed to compare echocardiography and biomarker profile between sRV patients with and without HF and patients with a systemic left ventricle diagnosed with HF (sLV-HF).

Methods And Results: Eighty-seven sRV patients and 30 sLV-HF patients underwent echocardiographic evaluation and blood sampling.

View Article and Find Full Text PDF

Trophic niche adaptation of mountain frogs around the Sichuan Basin: individual specialization and response to climate variations.

Front Zool

December 2024

Chengdu Institute of Biology, Chinese Academy of Sciences, No. 23, Qunxian South Road, Tianfu New Area, Chengdu, 610213, China.

Background: Climatic and geographic variations have profound effects on the resource utilization of individuals and populations. Evaluating resource use in different environments is crucial for understanding species ecological adaptation strategies and promoting biodiversity conservation. Stable isotopes are widely used to assess trophic niches, providing quantitative indicators of ecological interactions between organisms and resource use in ecosystems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!