The effect of contact lens wear on dynamic ocular surface temperature.

Cont Lens Anterior Eye

Neurosciences Research Institute, School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham B47ET, UK.

Published: March 2005

Aim: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses.

Method: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 +/- 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n=8) or continuous wear (LCW; n=8) basis; balafilcon-A contact lenses on a daily wear (BDW; n=8) or continuous wear (BCW; n=8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n=8); and no lenses (controls; n=8). OST was measured continuously five times, for 8s after a blink, following a minimum of 2h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated.

Results: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 +/- 1.7 degrees C versus 35.0 +/- 1.1 degrees C; p < 0.005), predominantly in the LCW group (38.6 +/- 1.0 degrees C; p < 0.0001). Lens surface temperature was highly correlated (r=0.97) to, but lower than OST (by -0.62 +/- 0.3 degrees C). There was no difference with modality of wear (DW 37.5 +/- 1.6 degrees C versus CW 37.8+/-1.9 degrees C; p=0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 +/- 1.1 degrees C versus 37.5 +/- 1.5 degrees C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p=0.07) or without (p=0.47) lenses in situ.

Conclusions: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2004.10.001DOI Listing

Publication Analysis

Top Keywords

+/- degrees
28
contact lens
16
ocular surface
16
surface temperature
16
contact lenses
16
lens wear
12
temperature changes
12
lenses daily
12
degrees versus
12
wear
10

Similar Publications

Objective: This retrospective cohort study aims to evaluate and compare different postoperative pain management strategies for esophageal squamous cell carcinoma (ESCC), in order to provide scientific evidence for clinical practice and decision-making.

Methods: A total of 274 ESCC patients who underwent surgery at the Affiliated Huai'an No. 1 People's Hospital of Nanjing Medical University were included in the study.

View Article and Find Full Text PDF

Background: Rural School Support Strategies (RS3) is a bundle of implementation supports (including training, technical assistance, and a virtual learning collaborative) designed for the scale-up of universal prevention initiatives. This study addresses mechanisms of action, exploring whether positive effects of RS3 on implementation fidelity are attributable to improvements in functioning of school implementation teams, and increases in organizational readiness.

Methods: Data are from a cluster-randomized hybrid Type 3 implementation-effectiveness trial of RS3 among rural Idaho schools implementing Positive Behavioral Interventions and Supports (PBIS).

View Article and Find Full Text PDF

Background: Changes in amyloid beta (Aβ) and phosphorylated tau brain levels are known to affect brain network organization but very little is known about how plasma markers can relate to these measures. We aimed to address the relationship between centrality network changes and two plasma pathology markers: phosphorylated tau at threonine 231 (p-tau231), a proxy for early Aβ change, and neurofilament light chain (Nfl), a marker of axonal degeneration.

Methods: One hundred and four cognitively unimpaired individuals were divided into a high pathology load (33 individuals; HP) group and a low pathology (71 individuals; LP) one.

View Article and Find Full Text PDF

Comprehensive analysis of scRNA-seq and bulk RNA-seq reveals the non-cardiomyocytes heterogeneity and novel cell populations in dilated cardiomyopathy.

J Transl Med

January 2025

State Key Laboratory of Cardiovascular Diseases and Medical Innovation Center, School of Medicine, Shanghai East Hospital, Tongji University, Shanghai, 200120, China.

Background: Dilated cardiomyopathy (DCM) is one of the most common causes of heart failure. Infiltration and alterations in non-cardiomyocytes of the human heart involve crucially in the occurrence of DCM and associated immunotherapeutic approaches.

Methods: We constructed a single-cell transcriptional atlas of DCM and normal patients.

View Article and Find Full Text PDF

Companion animal and equine clinical research: a Nordic perspective.

Acta Vet Scand

January 2025

Department of Clinical Sciences, Faculty of Veterinary Medicine and Animal Science, Swedish University of Agricultural Sciences, PO Box 7054, 750 07, Uppsala, Sweden.

Background: The societal value of cats, dogs and horses is high, and the companion and sport animal health care sector is growing. Clinical research concerning cats, dogs and horses is crucial for the development of evidence-based medical care that benefits animals and their owners, and has implications for human and environmental health from a One Health perspective. Basic information on companion animal and equine research enables more directed measures to improve conditions for research within the area.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!