A biochip based on surface plasmon resonance was fabricated to detect prostate specific antigen-alpha(1)-antichymotrypsin (PSA-ACT complex) in both HBS buffer and human serum. To reduce non-specific binding and steric hindrance effect, the chemical surface of the sensor chips was constructed by using various oligo(ethylene glycol) mixtures of different molar ratios of HS(CH2)11(OCH2CH2)6OCH2COOH and HS(CH2)11(OCH2CH2)3OH. The self-assembled monolayers were biotinylated to facilitate the immobilization of streptavidin. Using the chip surfaces, PSA-ACT complex in HBS buffer and human serum was detected at 20.7 and 47.5 ng/ml by primary immunoresponse, respectively. However, the limit of detection could be simply enhanced by a sandwich strategy to improve the sensitivity and specificity of the immunoassay. An intact PSA polyclonal antibody was used as an amplifying agent in the strategy. As a result, PSA-ACT complex concentrations as low as 10.2 and 18.1 ng/ml were found in the HBS buffer and human serum sample, respectively. The result indicates that this approach could satisfy our goal without modifying the secondary interactant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2005.10.014DOI Listing

Publication Analysis

Top Keywords

psa-act complex
12
hbs buffer
12
buffer human
12
human serum
12
sensitivity specificity
8
prostate specific
8
specific antigen-alpha1-antichymotrypsin
8
based surface
8
surface plasmon
8
plasmon resonance
8

Similar Publications

In this prospective study we examined the utility of parameters obtained on prostate needle biopsy and prostate specific antigen-alpha(1)-antichymotripsine complex (PSA-ACT) to predict adverse pathologic findings after radical prostatectomy. 45 consecutive patients assigned for radical prostatectomy due to clinically localized prostate cancer were included in the study. Prostate biopsy parameters such as number of positive cores, the greatest percentage of tumor in the positive cores, Gleason score, perineural invasion, unilaterality or bilaterality of the tumor were recorded.

View Article and Find Full Text PDF

Background: PSA is a biomarker for diagnosis and management of prostate cancer. PSA is known to have anti-tumorigenic activities, however, the physiological role of PSA in prostate tumor progression is not well understood.

Methods: Five candidate peptides identified based upon computer modeling of the PSA crystal structure and hydrophobicity were synthesized at >95% purity.

View Article and Find Full Text PDF

Reduced graphene oxide field-effect transistor for label-free femtomolar protein detection.

Biosens Bioelectron

March 2013

Department of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 440-746, Korea.

We report reduced graphene oxide field effect transistor (R-GO FET) biosensor for label-free ultrasensitive detection of a prostate cancer biomarker, prostate specific antigen/α1-antichymotrypsin (PSA-ACT) complex. The R-GO channel in the device was formed by reduction of graphene oxide nanosheets networked by a self-assembly process. Immunoreaction of PSA-ACT complexes with PSA monoclonal antibodies on the R-GO channel surface caused a linear response in the shift of the gate voltage, V(g,min), where the minimum conductivity occurs.

View Article and Find Full Text PDF

PSA forms complexes with α1-antichymotrypsin in prostate.

Prostate

January 2013

Department of Clinical Chemistry, University of Helsinki and Helsinki University Central Hospital, FIN-00014 University of Helsinki, Helsinki, Finland.

Background: PSA is the most useful prostate cancer marker. However, its levels are increased also in some non-malignant conditions. In circulation, the majority of PSA is complexed with protease inhibitors, including α(1) -antichymotrypsin (ACT).

View Article and Find Full Text PDF

Enhancement of sensitivity using hybrid stimulus for the diagnosis of prostate cancer based on polydiacetylene (PDA) supramolecules.

Biosens Bioelectron

December 2010

School of Chemical Engineering, Sungkyunkwan University, 300 Cheoncheon-dong, Jangan-gu, Suwon, Gyeonggi-do 440-746, South Korea.

In this study, hybrid stimulus was initially introduced to improve the sensitivity of PDA vesicle chip for detection of prostate-specific antigen-α1-antichymotrypsin (PSA-ACT) complex. The strategy of hybrid stimulus on PDA vesicle chip offers the amplification method of fluorescent signal which combines a primary response by the immune reaction of antigen-antibody and a secondary response by the mechanical pressure of pAb-conjugated magnetic beads. As the primary response result on PDA vesicle chip, the PSA-ACT complex in PBS buffer was detected at 10 ng/mL.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!