In order to assess the quality of freshly isolated and cultivated pancreatic islets designed for experimental transplantation in rats we combined the vitality staining test, in vitro measurement of insulin secretion capacity, and assessment of islet respiration. Oxygen consumption was measured using the respirometer Oxygraph 2K equipped with polarographic oxygen sensors. The results of oxymetry demonstrated a linear correlation between islet number and oxygen consumption. Respiration per unit of viable islet tissue was constant. Oxygen consumption tests were in good correlation with the results of insulin release assays, with a correlation coefficient of 0.82. We found no significant differences in all three vitality-testing methods performed with fresh and 24-hour cultivated islets (P > .05). We conclude that polarographic oxymetry provides a fast and easy evaluation test of islet quality. After appropriate standardization, the oxymetric technique can be used for routine clinical pretransplant islet quality testing. In addition, cell membrane integrity and mitochondrial function could be assessed after addition of specific respiration inhibitors or stimulators.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.transproceed.2005.09.053 | DOI Listing |
Naunyn Schmiedebergs Arch Pharmacol
January 2025
School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, 1988873554, Iran.
Gastric ulcers (GUs) represent a common gastrointestinal disorder characterized by mucosal damage and inflammation, often precipitated by factors such as Helicobacter pylori infection and the consumption of COX inhibitors. This comprehensive review investigates the role of oxidative stress and inflammation in the pathogenesis of GUs and assesses the potential therapeutic effects of Punica granatum (pomegranate, Pg) supplementation. Utilizing a series of experimental models, including indomethacin, aspirin, and alcohol-induced ulcers, we demonstrate that Pg extracts possess significant gastroprotective properties.
View Article and Find Full Text PDFScand J Med Sci Sports
February 2025
School of Kinesiology, The University of Western Ontario, London, Ontario, Canada.
We assessed the validity, reliability, and transferability of gas exchange and ventilatory variables from two commonly used metabolic measurement systems (COSMED Quark and VO2Master Pro). Two identical devices from each system were independently connected to a metabolic simulator (VacuMed), and 2 min of steady-state data was recorded at simulated oxygen uptake (V̇O) of 1, 2, 3, and 4 L∙min achieved through minute ventilation (V̇) of 30, 60, 105, and 150 L∙min. Each metabolic analyzer recorded data three times for each "intensity" in a randomized order, and assessments were completed on two separate days.
View Article and Find Full Text PDFPhysiother Res Int
April 2025
Department of Rehabilitation and Care, Hatsudai Rehabilitation Hospital, Tokyo, Japan.
Background And Purpose: Patient education on physical activity (PA) requires a clear understanding of PA intensity. However, there is no organized list of PAs intensities specific to individuals with stroke. This review aimed to clarify the intensity of PAs in people with stroke and summarize the methodologies and participant characteristics in previous investigations of energy expenditure (EE) during PAs.
View Article and Find Full Text PDFAdv Healthc Mater
January 2025
State Key Laboratory of Separation Membranes and Membrane Processes & Key Laboratory of Hollow Fiber Membrane Materials and Membrane Processes (MOE) & Tianjin Key Laboratory of Hollow Fiber Membrane Materials and Processes, School of Materials Science and Engineering, Tiangong University, Tianjin, 300387, P. R. China.
Sepsis is an underappreciated yet severe threat to human life, marked by organ dysfunction and high mortality resulting from disordered inflammatory responses to blood infection. Unfortunately, no specific drugs are available for effective sepsis treatment. As a pivotal biomarker for sepsis, lactate levels are closely related to vascular permeability and sepsis-associated mortality.
View Article and Find Full Text PDFSmall
January 2025
College of Materials Science and Engineering, Nanjing Tech University, No. 30 South Puzhu Road, Nanjing, Jiangsu, 211816, China.
Protonic ceramic cells (PCCs) have been identified as promising energy conversion devices, offering flexible fuel options and reduced operating consumption at intermediate temperatures. However, the application of traditional cobalt-based perovskite air electrodes in PCCs is hindered by their insufficient durability and high coefficient of thermal expansion. In this study, a straightforward metal-oxygen bond engineering is conducted, introducing a single-phase perovskite, BaLa(FeZn)NO (BLFZN0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!