The aim of this review is to report on studies of hydroxyapatite-coated external fixation pins as a solution to enhance pin fixation. In a highly loaded animal study, three tapered pin types were compared: Type A uncoated, Type B coated with hydroxyapatite and Type C coated with titanium. There was a 13-fold increase in the extraction torque of Type B pins compared with Type A, and a twofold increase compared with Type C pins. Extraction torque was significantly lower compared with the corresponding insertion torque in both Types A (p < 0.001) and C (p = 0.003). Conversely, with the hydroxyapatite-coated pins there was no difference between extraction and insertion torque. In a clinical study of 76 external fixation pins in 19 patients treated with hemicallotasis for osteoarthritis on the medial side of the knee, pin insertion and extraction torque forces were measured. The patients were randomized to be treated with either standard tapered pins or tapered pins coated with hydroxyapatite. Extraction torque of the hydroxyapatite-coated pins was higher than the extraction torque of the standard pins in both cancellous and cortical bone (p < 0.005). In a prospective, randomized clinical study of osteoporotic wrist fractures, extraction torque of the coated pins was higher than with standard pins (p < 0.0001). These studies demonstrate that with the use of hydroxyapatite-coated pins, no deterioration of pin fixation occurs, and that there is no significant pin loosening and infection, regardless of bone type and loading conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1586/17434440.2.4.465 | DOI Listing |
Front Med Technol
December 2024
Institute of Systems and Information Engineering, University of Tsukuba, Tsukuba, Japan.
Introduction: The wearable cyborg Hybrid Assistive Limb (HAL) is a therapeutic exoskeletal device that provides voluntary gait assistance using kinematic/kinetic gait data and bioelectrical signals. By utilizing the gait data automatically measured by HAL, we are developing a system to analyze the wearer's gait during the intervention, unlike conventional evaluations that compare pre- and post-treatment gait test results. Despite the potential use of the gait data from the HAL's sensor information, there is still a lack of analysis using such gait data and knowledge of gait patterns during HAL use.
View Article and Find Full Text PDFDent Res J (Isfahan)
November 2024
Department of Orthodontics and Dentofacial Orthopedics, SRM Dental College and Hospital, Chennai, Tamil Nadu, India.
Background: The aim of this study was to compare the mechanical properties of the polymer brackets with metal and ceramic brackets and verify if the polymer brackets could be used clinically.
Materials And Methods: A thorough search was conducted in four electronic databases, including Scopus, PubMed, Cochrane, Ovid, and Lilacs, with article selection based on Preferred Reporting Items for Systematic Reviews and Meta-Analysis standards. A computerized search of the database was done from January 1990 to June 2024.
Arch Phys Med Rehabil
December 2024
Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, The Netherlands.
Objectives: To investigate the acute (directly post-stretching) and long-term (≥1 week of treatment) effects of stretching type, duration, and intensity on joint range of motion (ROM) and stiffness in ankle contractures.
Data Sources: PubMed, Embase.com, Clarivate Analytics/Web of Science Core Collection, EBSCO/SPORTDiscus, and EBSCO/CINAHL were searched for studies published in English from inception until September 12, 2023.
Phys Rev E
November 2024
Institut für Theoretische Physik, Technikerstraße 21-A, Universität Innsbruck, A-6020 Innsbruck, Austria.
We analyze gravitaxis of a Brownian circle swimmer by deriving and analytically characterizing the experimentally measurable intermediate scattering function (ISF). To solve the associated Fokker-Planck equation, we use a spectral-theory approach, finding formal expressions in terms of eigenfunctions and eigenvalues of the overdamped-noisy-driven pendulum problem. We further perform a Taylor series of the ISF in the wavevector to extract the cumulants up to the fourth order.
View Article and Find Full Text PDFClin Oral Implants Res
December 2024
ARTORG Centre for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Objectives: Primary stability (PS) is a key factor for promoting osseointegration and long-term success of dental implants particularly for immediate loading protocols. Beyond the current assessments of PS, an accurate pre-operative evaluation of PS would contribute to the improvement of surgical planning and treatment outcome. This study used biomechanical testing and homogenized finite element (hFE) analysis to objectively measure PS in the laboratory, and digitally estimate PS from prior μCT reconstructions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!