An integrated semicompliant balloon ultrasound catheter for quantitative feedback and image guidance during stent deployment.

IEEE Trans Ultrason Ferroelectr Freq Control

Department of Biomedical Engineering, University of Michigan, Ann Arbor 48109-209, USA.

Published: September 2005

An integrated balloon ultrasound catheter prototype was designed to image from inside the balloon for real-time guidance during stent deployment. It was fabricated using a semicompliant balloon material (polyethylene) and a 20 MHz, 64-element circumferential ultrasound array. A commercial stent, nominally 4.4 mm in diameter and 12 mm in length, was used for a phantom study and placed along the length of the integrated balloon ultrasound catheter. A rubber phantom was created with an elastic modulus of 175 kPa with a 4.36 mm diameter lumen. Real-time balloon pressure measurements were recorded using a digital pressure sensor, and real-time radio-frequency (RF) data were captured as the balloon was inflated. The slope of the area-pressure ratio (APR) was compared to a reference measure of the balloon and stent expanded in water to determine a measure for optimal stent deployment. The results clearly indicate stent deployment at 11.1 atm using this metric. The APR slope could serve as quantitative feedback parameter for guiding stent deployment to reduce arterial injury and subsequent restenosis. After the stent deployment experiment, RF data were captured as the balloon catheter was moved along the length of the stent in pullback mode to confirm successful stent deployment. Ultimately, an integrated balloon ultrasound catheter could serve as a single catheter intervention device by providing real-time intravascular ultrasound (IVUS) imaging and quantitative feedback during stent deployment.

Download full-text PDF

Source
http://dx.doi.org/10.1109/tuffc.2005.1516022DOI Listing

Publication Analysis

Top Keywords

stent deployment
32
balloon ultrasound
16
ultrasound catheter
16
quantitative feedback
12
integrated balloon
12
stent
11
balloon
10
semicompliant balloon
8
guidance stent
8
deployment
8

Similar Publications

Unlabelled: Pulmonary vein (PV) stenosis is a rare complication following PV isolation (PVI) for atrial fibrillation. Despite the benefit of early intervention, screening is not conducted, emphasizing the importance of maintaining a high index of suspicion. Standardized management approaches are unavailable for this serious complication.

View Article and Find Full Text PDF

Introduction: Coarctation of the aorta is a congenital narrowing of the thoracic aorta associated with hypertension and significant pressure gradients across the coarctation site. Coarctoplasty by percutaneous approach is the preferred method of treatment. However, complications like stent dislodgement may result and must be immediately managed to prevent adverse outcomes.

View Article and Find Full Text PDF

Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.

Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.

View Article and Find Full Text PDF

Coronary artery calcification is an impediment to percutaneous coronary interventions by obstructing the device pathway or stent deployment. To facilitate percutaneous coronary intervention in such complex lesions, high-pressure balloon dilations, atherectomy procedures, and specialty balloons are used but they all come with considerable limitations and periprocedural complications like dissection and perforation. To surpass these disadvantages, intravascular lithotripsy was introduced which acts by delivering high-pressure pulsatile sonic waves circumferentially thereby destroying the calcium deposits.

View Article and Find Full Text PDF

Impact of coronary flow restoration just before stent deployment in primary percutaneous coronary intervention.

Cardiovasc Interv Ther

January 2025

Division of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama City, 330-8503, Japan.

This study aimed to investigate the relationship between the restoration of coronary flow just before stent deployment and the final thrombolysis in myocardial infarction (TIMI) flow grade 3 in patients with ST-segment elevation myocardial infarction (STEMI) whose initial TIMI flow grade ≤ 1. In primary percutaneous coronary intervention (PCI), initial TMI flow grade ≤ 1 is closely associated with suboptimal final TIMI flow grade. We included 466 STEMI patients with initial TIMI flow grade ≤ 1 and divided into a restored flow group or an unrestored flow group according to the TIMI flow grade just before stent deployment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!