An integrated balloon ultrasound catheter prototype was designed to image from inside the balloon for real-time guidance during stent deployment. It was fabricated using a semicompliant balloon material (polyethylene) and a 20 MHz, 64-element circumferential ultrasound array. A commercial stent, nominally 4.4 mm in diameter and 12 mm in length, was used for a phantom study and placed along the length of the integrated balloon ultrasound catheter. A rubber phantom was created with an elastic modulus of 175 kPa with a 4.36 mm diameter lumen. Real-time balloon pressure measurements were recorded using a digital pressure sensor, and real-time radio-frequency (RF) data were captured as the balloon was inflated. The slope of the area-pressure ratio (APR) was compared to a reference measure of the balloon and stent expanded in water to determine a measure for optimal stent deployment. The results clearly indicate stent deployment at 11.1 atm using this metric. The APR slope could serve as quantitative feedback parameter for guiding stent deployment to reduce arterial injury and subsequent restenosis. After the stent deployment experiment, RF data were captured as the balloon catheter was moved along the length of the stent in pullback mode to confirm successful stent deployment. Ultimately, an integrated balloon ultrasound catheter could serve as a single catheter intervention device by providing real-time intravascular ultrasound (IVUS) imaging and quantitative feedback during stent deployment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/tuffc.2005.1516022 | DOI Listing |
J Cardiol Cases
October 2024
Department of Cardiology, Mater Dei Hospital, Msida, Malta.
Unlabelled: Pulmonary vein (PV) stenosis is a rare complication following PV isolation (PVI) for atrial fibrillation. Despite the benefit of early intervention, screening is not conducted, emphasizing the importance of maintaining a high index of suspicion. Standardized management approaches are unavailable for this serious complication.
View Article and Find Full Text PDFInt J Surg Case Rep
January 2025
Students' Scientific Research Center, Tehran University of Medical Sciences, Tehran, Iran. Electronic address:
Introduction: Coarctation of the aorta is a congenital narrowing of the thoracic aorta associated with hypertension and significant pressure gradients across the coarctation site. Coarctoplasty by percutaneous approach is the preferred method of treatment. However, complications like stent dislodgement may result and must be immediately managed to prevent adverse outcomes.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine.
Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.
Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.
Cardiol Rev
January 2025
Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York City, NY.
Coronary artery calcification is an impediment to percutaneous coronary interventions by obstructing the device pathway or stent deployment. To facilitate percutaneous coronary intervention in such complex lesions, high-pressure balloon dilations, atherectomy procedures, and specialty balloons are used but they all come with considerable limitations and periprocedural complications like dissection and perforation. To surpass these disadvantages, intravascular lithotripsy was introduced which acts by delivering high-pressure pulsatile sonic waves circumferentially thereby destroying the calcium deposits.
View Article and Find Full Text PDFCardiovasc Interv Ther
January 2025
Division of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama City, 330-8503, Japan.
This study aimed to investigate the relationship between the restoration of coronary flow just before stent deployment and the final thrombolysis in myocardial infarction (TIMI) flow grade 3 in patients with ST-segment elevation myocardial infarction (STEMI) whose initial TIMI flow grade ≤ 1. In primary percutaneous coronary intervention (PCI), initial TMI flow grade ≤ 1 is closely associated with suboptimal final TIMI flow grade. We included 466 STEMI patients with initial TIMI flow grade ≤ 1 and divided into a restored flow group or an unrestored flow group according to the TIMI flow grade just before stent deployment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!