Background: The QUALIOST was designed for use with the SF-36 to measure established osteoporosis-specific quality of life (QoL). The reliability (internal consistency and test-retest) and validity of the questionnaire were established in a stand-alone psychometric validation study. The objective of this paper is to provide additional information on the instrument's responsiveness using clinical trial data, along with the reliability and validity of translated versions.

Methods: The Spinal Osteoporosis Therapeutic Intervention (SOTI) was an international clinical trial comparing strontium ranelate to placebo on the occurrence of new vertebral fracture in patients with postmenopausal osteoporosis. QoL was a secondary endpoint, assessed using the SF-36 and QUALIOST at baseline and every six months, with the main analysis at 3-year follow-up. Questionnaire acceptability, analysis of the hypothesised structure, internal consistency reliability and responsiveness to clinical change over time were assessed at the 3-year follow up.

Results: 1592 patients from 11 countries completed at least one QoL questionnaire. The psychometric properties of the questionnaires were assessed on cross-sectional (N = 1486) and longitudinal (N = 1288) data. Item discriminant validity of the QUALIOST was excellent, as was item convergent validity, with 100% of item-scale correlations being above the 0.40 level. Internal consistency reliability was also extremely good, with high Cronbach's alpha scores above the 0.70 benchmark. Responsiveness results were consistent for all QUALIOST scores, indicating that greater decreases in QoL corresponded to greater numbers of fractures experienced. QUALIOST scores also differed according to the type of fracture suffered. This was demonstrated by increased effect sizes for more severe vertebral fractures (clinical vertebral and painful vertebral). In comparing responsiveness, the QUALIOST scores were generally more consistent than those of the SF-36. Most notably, the QUALIOST was more responsive with regard to painful vertebral fractures than the SF-36.

Conclusion: The QUALIOST is a reliable and valid tool for measuring QoL in postmenopausal osteoporotic women. Being available in several validated language versions, it is ready to be used in a variety of settings, including international clinical trials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1325267PMC
http://dx.doi.org/10.1186/1477-7525-3-69DOI Listing

Publication Analysis

Top Keywords

internal consistency
12
qualiost scores
12
qualiost
9
responsiveness qualiost
8
quality life
8
responsiveness clinical
8
clinical trial
8
international clinical
8
consistency reliability
8
vertebral fractures
8

Similar Publications

Research Tools for Eating Behavior in People with Autism Spectrum Disorder (ASD).

J Autism Dev Disord

January 2025

Federal Technological University of Paraná, Postgraduate Program in Science and Technology Teaching (PPGECT), Ponta Grossa, Paraná, Brasil.

Objective: To identify the tools used to assess eating behaviors in individuals with Autism Spectrum Disorder (ASD) and summarize their distribution, citation rates, journal publication, JCR scores, and psychometric properties.

Methods: A literature review was conducted to identify studies on eating behavior in individuals with ASD. The search included various descriptors and combinations of keywords in databases such as Medline/PubMed, Science Direct, Scopus, SciELO, and Web of Science.

View Article and Find Full Text PDF

This study investigates the performance of the Depression, Anxiety, and Stress Scale-21 (DASS-21) across diverse demographic groups during the COVID-19 pandemic. Utilizing a large, generalizable U.S.

View Article and Find Full Text PDF

The PERFORMANCE II Trial: A Prospective Multicenter Investigation of a Novel Carotid Stent System.

JACC Cardiovasc Interv

December 2024

Department for Angiology, Brandenburg Medical School Theodor Fontane, Campus Clinic Brandenburg, Center for Internal Medicine I, Berlin, Germany; Department of Angiology, Sankt-Gertrauden-Krankenhaus, Berlin, Germany.

Background: Several randomized clinical trials have shown that the composite endpoint of death, stroke, and myocardial infarction (MI) is equivalent between carotid artery stenting and carotid endarterectomy. However, the risk of minor stroke has been consistently higher with carotid artery stenting.

Objectives: The authors sought to evaluate the safety and effectiveness of a novel carotid stent system comprised of a stent, an adjustable integrated embolic filter and a postdilation balloon, in patients at elevated risk for adverse events from carotid endarterectomy.

View Article and Find Full Text PDF

The case report presents a male patient in his mid-60s with a history of hypertension, benign prostatic hyperplasia and chronic kidney disease (CKD). He presented with gradually increasing serum creatinine levels and hyperglobulinemia, leading to suspicion of multiple myeloma. However, subsequent testing revealed features consistent with systemic lupus erythematosus (SLE) and IgG4-related kidney disease (IgG4-RKD).

View Article and Find Full Text PDF

Background: After breast cancer (BC), women may face other severe symptoms such as sleep problems. The use of simple, fast, and reliable scales is necessary in the clinic to improve patient benefits, and sleep is an important aspect to be addressed.

Objective: This study was conducted to adapt and validate the Spanish version of the satisfaction, alertness, timing, efficiency, and duration (SATED) scale for measuring sleep health in women who have completed treatment for BC in Spain (SATED-BC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!