Atherosclerosis was induced in 20 Hanford miniature swine. Subsequently, one iliac artery lesion in each of 16 pigs was stented with either a self-expanding (8 pigs) or a balloon-expanded (8 pigs) stent. Immediately after stent placement, 4 animals in each group were taken off the atherogenic diet and continued on normal chow for the remainder of the study. Four months after stents were placed, atherosclerosis and the mural changes associated with the stent were more clearly evident in the arteries of the pigs continued on the atherogenic diet. These pigs also exhibited significantly more neointimal proliferation. In addition, the arteries containing the balloon-expanded stents showed more extensive and complex intimal changes when compared with arteries with self-expanding stents. Although both stent designs were equally effective in maintaining vascular patency, the balloon-expanded stent was more traumatic to the vessel wall which resulted in a significantly greater neointimal thickness.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02735576DOI Listing

Publication Analysis

Top Keywords

balloon-expanded stents
8
stents atherosclerosis
8
atherogenic diet
8
pigs
5
stent
5
treatment experimentally
4
experimentally induced
4
induced atherosclerosis
4
atherosclerosis swine
4
swine iliac
4

Similar Publications

Percutaneous coronary intervention of a severely calcified coronary artery stenosis is associated with stent underexpansion and adverse outcomes. Intravascular lithotripsy (IVL) is a novel technology for fracturing calcified plaque in the coronary artery. We describe the first case of a severely calcified, undilatable coronary artery lesion.

View Article and Find Full Text PDF

Background: In-stent restenosis (ISR) is a crucial factor that affects the long-term efficacy of intracranial bare metal stent (BMS) implantation for intracranial atherosclerotic stenosis (ICAS). Patients with intracranial ISR are at a high risk of recurrent ischaemic events. The NOVA intracranial drug-eluting stent (DES) trial demonstrates that a DES can reduce ISR and stroke recurrence after intracranial bare stent implantation.

View Article and Find Full Text PDF

Iatrogenic subclavian artery rupture: A unique case report on balloon occlusion.

Int J Surg Case Rep

August 2023

Division of Vascular Surgery, Department of Surgery, St. Barnabas Hospital, Bronx, NY 10457, United States of America.

Introduction: Inadvertent subclavian artery puncture during attempted central venous catheterization can be devastating. Percutaneous stent grafting, closure devices and conventional surgery have been described to effect repair. Balloon occlusion has also been described and often recommended.

View Article and Find Full Text PDF

Hemodynamic follow-up after valve-in-valve TAVR for failed aortic bioprosthesis.

J Card Surg

December 2022

Medical Faculty "Carl Gustav Carus", TU Dresden, Dresden, Germany.

Background: "valve-in-valve" TAVR (VIV-TAVR) is established and provides good initial clinical and hemodynamic outcomes. Lacking long-term durability data baffle the expand to lower risk patients. For those purposes, the present study adds a hemodynamic 3-years follow-up.

View Article and Find Full Text PDF

Introduction: Extracranial internal carotid artery (ICA) pseudoaneurysms in children, although uncommon, are life threatening. Covered stents are a good alternative treatment, as they avoid the risk of open surgery and preserve the ICA. Until recently, long term outcomes were unknown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!