Mach-Zehnder interferometry in a strongly driven superconducting qubit.

Science

MIT Lincoln Laboratory, 244 Wood Street, Lexington, MA 02420, USA.

Published: December 2005

We demonstrate Mach-Zehnder-type interferometry in a superconducting flux qubit. The qubit is a tunable artificial atom, the ground and excited states of which exhibit an avoided crossing. Strongly driving the qubit with harmonic excitation sweeps it through the avoided crossing two times per period. Because the induced Landau-Zener transitions act as coherent beamsplitters, the accumulated phase between transitions, which varies with microwave amplitude, results in quantum interference fringes for n = 1 to 20 photon transitions. The generalization of optical Mach-Zehnder interferometry, performed in qubit phase space, provides an alternative means to manipulate and characterize the qubit in the strongly driven regime.

Download full-text PDF

Source
http://dx.doi.org/10.1126/science.1119678DOI Listing

Publication Analysis

Top Keywords

mach-zehnder interferometry
8
avoided crossing
8
qubit
6
interferometry driven
4
driven superconducting
4
superconducting qubit
4
qubit demonstrate
4
demonstrate mach-zehnder-type
4
mach-zehnder-type interferometry
4
interferometry superconducting
4

Similar Publications

This study investigates the optical, mechanical, and antimicrobial properties of polypropylene (PP) fibers enhanced with titanium dioxide (TiO) and zinc oxide (ZnO) nanoparticles. Using a Mach-Zehnder interferometric system, we examined the refractive indices, birefringence, and opto-mechanical behavior of blank PP, PP/TiO, and PP/ZnO nanocomposite fibers under various conditions, including different polarization orientations and during cold drawing processes. The 2D Fourier transform algorithm is employed to analyze interferometric data, enabling precise measurements of refractive index profiles and birefringence.

View Article and Find Full Text PDF

Significance: Optical coherence tomography (OCT) images are prone to image artifacts due to the birefringence of the sample or the optical system when a polarized light source is used for imaging. These artifacts can lead to degraded image quality and diagnostic information.

Aim: We aim to mitigate these birefringence-related artifacts in OCT images by adding a depolarizer module in the reference arm of the interferometer.

View Article and Find Full Text PDF

The statistical properties of the detection events constituting the interference fringes at the output of an interferometer are well-known. Nevertheless, there is still no unified view of what is happening to a quantum system inside an interferometer. Strong measurements of path operators destroy the interference effect.

View Article and Find Full Text PDF

Balloon-Shaped SMF Blood Glucose Concentration and Temperature Sensor Based on Core-Offset Structure.

Sensors (Basel)

September 2024

Engineering Research Center of Optoelectronic Devices and Communication Technology, Ministry of Education, Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, China.

A blood glucose concentration and temperature sensor with a balloon-shaped single-mode fiber (SMF) based on a core-offset structure is proposed and experimentally demonstrated. The balloon-shaped SMF is created by offset-fusing a straight-line SMF between two other SMFs, thereby forming a Mach-Zehnder interferometer (MZI). The core-offset structure can effectively excite higher-order cladding modes.

View Article and Find Full Text PDF

Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach-Zehnder Interferometer.

Sensors (Basel)

September 2024

State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.

Article Synopsis
  • A fiber Bragg grating (FBG) pulse and systolic blood pressure measurement system uses the edge-filtering method with a Mach-Zehnder interferometer (MZI) design for effective data capture.
  • The system can measure pulse at three different wrist positions and determines systolic blood pressure using the pulse transit time principle, showing a high accuracy with a small margin of error compared to standard monitors.
  • It offers continuous real-time monitoring, fast detection, stable performance, and comfort for the user, making it valuable for health monitoring and medical device innovation.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!