A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Testing for fetal exposure to illicit drugs using umbilical cord tissue vs meconium. | LitMetric

Testing for fetal exposure to illicit drugs using umbilical cord tissue vs meconium.

J Perinatol

Department of Women and Newborns, Intermountain Health Care and McKay Dee Hospital, Ogden, UT 84403, and Department of Family and Preventive Medicine, University of Utah, Salt Lake City, UT, USA.

Published: January 2006

Objective: We assessed the agreement of testing for fetal exposure to illicit drugs contrasting paired specimens of meconium vs umbilical cord tissue.

Methods: We obtained paired samples of meconium and umbilical cord tissue from 118 pregnancies with high suspicion of illicit drug use by the mothers. Each specimen was tested for amphetamines, opiates, cocaine, cannabinoids, and phencyclidine using drug class-specific immunoassays.

Results: The agreement of drug screening results between cord and meconium was above 90% for all drugs tested. Meconium identified 21 cases as positive for amphetamines. The paired cord identified 20 of these, and in addition identified three other positives that the meconium labeled as negative. Gas chromatography-mass spectrometry confirmed these three cord samples as methamphetamine positive. Meconium identified 97 samples that were negative for amphetamines, while the cord identified 94 of these as negative but three as positive. Agreement of cord with meconium for amphetamines was 96.6%. The concordance for opiates was 94.9%, for cocaine was 99.2%, and for cannabinoids was 90.7%.

Conclusions: Umbilical cord tissue performs as well as meconium in assessing fetal drug exposure to amphetamines, opiates, cocaine, and cannabinoids. Results of studies using the cord may have a more rapid return to the clinician, because waiting for meconium to be passed sometimes requires several days. Moreover, in some cases the meconium is passed in utero making collection impossible, whereas cord should always be available for drug testing.

Download full-text PDF

Source
http://dx.doi.org/10.1038/sj.jp.7211416DOI Listing

Publication Analysis

Top Keywords

umbilical cord
16
cord tissue
12
cord
11
meconium
11
testing fetal
8
fetal exposure
8
exposure illicit
8
illicit drugs
8
meconium umbilical
8
amphetamines opiates
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!