A universal noise removal algorithm with an impulse detector.

IEEE Trans Image Process

Department of Mathematics, Washington University in Saint Louis, MO 63130, USA.

Published: November 2005

We introduce a local image statistic for identifying noise pixels in images corrupted with impulse noise of random values. The statistical values quantify how different in intensity the particular pixels are from their most similar neighbors. We continue to demonstrate how this statistic may be incorporated into a filter designed to remove additive Gaussian noise. The result is a new filter capable of reducing both Gaussian and impulse noises from noisy images effectively, which performs remarkably well, both in terms of quantitative measures of signal restoration and qualitative judgements of image quality. Our approach is extended to automatically remove any mix of Gaussian and impulse noise.

Download full-text PDF

Source
http://dx.doi.org/10.1109/tip.2005.857261DOI Listing

Publication Analysis

Top Keywords

impulse noise
8
gaussian impulse
8
universal noise
4
noise removal
4
removal algorithm
4
impulse
4
algorithm impulse
4
impulse detector
4
detector introduce
4
introduce local
4

Similar Publications

During acquisition and reconstruction, medical images may become noisy and lose diagnostic quality. In the case of CT scans, obtaining less noisy images results in a higher radiation dose being administered to the patient. Filtering techniques can be utilized to reduce radiation without losing diagnosis capabilities.

View Article and Find Full Text PDF

A novel quantitative diagnosis method for rolling bearing faults based on digital twin model.

ISA Trans

December 2024

Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing University of Technology, Beijing 100124, China. Electronic address:

Dual-impulse behaviors of rolling bearings have been widely researched for quantitative diagnosis. However, it is challenging to accurately extract entry and exit moments of the fault from noise-contaminated raw signals. To address this issue, a novel quantitative diagnosis method based on digital twin model is proposed to assess the fault severity from the original signal waveform.

View Article and Find Full Text PDF

Comparing saccades in Visually Enhanced Vestibular-Ocular Reflex and video head impulse test in vestibular assessment.

J Otol

July 2024

College of Otolaryngology Head and Neck Surgery, Chinese PLA General Hospital, Chinese PLA Medical School, 28 Fuxing Road, Beijing, China.

Objective: This study aimed to develop and evaluate a novel software tool for robust analysis of the Visually Enhanced Vestibular-Ocular Reflex (VVOR) and video head impulse test (vHIT) saccades.

Methods: A retrospective study was conducted on 94 patients with Meniere's Disease (MD), unilateral vestibular hypofunction (UVH), and vestibular migraine (VM). The MATLAB-based VVOR Analysis System and Saccades All in One software were utilized for data processing.

View Article and Find Full Text PDF

Guidelines for Diagnosis of Noise-Induced Hearing Loss and Their Specificity.

Clin Otolaryngol

December 2024

Consultant ENT Surgeon, Department of Otolaryngology Head and Neck Surgery, Manchester Royal Infirmary; Honorary Senior Lecturer, University of Manchester, Manchester, UK.

Objectives: A recent paper by Moore, Lowe and Cox has proposed guidelines for diagnosing noise-induced hearing loss (NIHL). It is referred to here as the MLC guidelines. Our aim was to assess the specificity of those guidelines (i.

View Article and Find Full Text PDF

Sensitive detection of incident acoustic waves over a broad frequency band offers a faithful representation of photoacoustic pressure transients of biological microstructures. Here, we propose a plasmon waveguide resonance sensor for responding to the photoacoustic impulses. By sequentially depositing Au, MgF, and SiO films on a coverslip, a composite waveguide layer produces a tightly confined optical evanescent field at the SiO-water interface with extremely strong electric field intensity, enabling the retrieval of photoacoustic signals with an estimated noise-equivalent-pressure (NEP) sensitivity of ∼92 Pa and a -6-dB bandwidth of ∼208 MHz.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!