AI Article Synopsis

  • The study evaluated the effects of dose-volume-time factors in 64 patients with localized prostate cancer who received high-dose-rate brachytherapy (HDR-BT) alongside external beam radiotherapy (EBRT).
  • Significant correlations were found between higher doses to the urethra and rectum and increased urinary morbidity and rectal bleeding, indicating specific dose limits for better outcomes.
  • The findings suggest that keeping the urethra dose below 15 Gy and the rectal mucosa dose below 6 Gy can help minimize treatment-related morbidity and highlight the importance of patient and treatment factors in managing toxicity.

Article Abstract

Background And Purpose: Evaluation of dose-volume-time-related factors in 64 patients treated with high-dose-rate brachytherapy (HDR-BT) as a boost to external beam radiotherapy (EBRT) for localized prostate cancer.

Patients And Methods: Clinical parameters were correlated with morbidity scores of the EPIC (Expanded Prostate Cancer Index) questionnaire. Median time after radiotherapy (HDR-BT up to 18 Gy in two fractions and EBRT up to a median dose of 50.4 Gy) was 1.5 and 3 years (first and second questionnaire).

Results: A significant impact of a urethra D1 exceeding 15 Gy in at least one HDR fraction concerning urinary morbidity and a rectum D1 exceeding 6 Gy to the rectal mucosa in the first and second HDR fraction concerning the rectal bleeding rate was found. A higher number of needles was associated with lower urinary and bowel scores after 1.5 years. A prostate length >4.8 cm and a longer duration of EBRT (independently of the dose) predisposed for lower urinary and bowel scores. In contrast to a urethra D1 > 15 Gy as an independent factor, a rectum D1 > 6 Gy per HDR fraction correlated with a higher number of needles and an increased prostate length.

Conclusions: To minimize morbidity in HDR-BT for prostate cancer, a maximum dose to the urethra of 15 Gy and a maximum dose to the rectal mucosa of 6 Gy is advisable. Treatment- and patient-related factors have a major impact on toxicity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2005.10.003DOI Listing

Publication Analysis

Top Keywords

hdr fraction
12
boost external
8
external beam
8
beam radiotherapy
8
localized prostate
8
prostate cancer
8
fraction concerning
8
rectal mucosa
8
higher number
8
number needles
8

Similar Publications

Purpose: To compare the clinical outcomes of two different schedules of modern image-guided adaptive brachytherapy (IGABT) in patients underwent chemoradiotherapy (CCRT) and high-dose rate (HDR) brachytherapy (BT) for locally advanced cervical cancer treated (LACC) METHODS AND MATERIALS: Data from medical records of all consecutive patients with histologically proven cervical cancer (FIGO 2018 stage IB-IVA) treated by HDR-BT after CCRT at our institution between 2016 and 2021 were reviewed.

Results: Two hundred and 8 patients with LACC FIGO 2018 stages (IB 20.7%; II 26.

View Article and Find Full Text PDF

Set-up errors are a problem for pre-clinical irradiators that lack imaging capabilities. The aim of this study was to investigate the impact of the potential set-up errors on the dose distribution for a mouse with a xenographic tumour irradiated with a standard Cs-137 cell irradiator equipped with an in-house lead collimator with 10 mm diameter apertures. The EGSnrc Monte-Carlo (MC) code was used to simulate the potential errors caused by displacements of the mouse in the irradiation setup.

View Article and Find Full Text PDF

: To analyze the results of interstitial (IRT) high-dose-rate (HDR) brachytherapy (BT) in the primary treatment of patients with unresectable superior sulcus tumors (SST) combined with external beam radiotherapy (EBRT). : Between 2013 and 2023, seven patients with unresectable SST were treated with combined BT and EBRT with or without concomitant chemotherapy. The patients' median age was 64 years (range, 49-79 years) and median tumor volume was 146.

View Article and Find Full Text PDF

Purpose: High-dose-rate brachytherapy (HDR-BT) combined with external beam radiotherapy (EBRT) is an effective treatment for patients with high- and very-high-risk prostate cancer. We sought to identify the factors associated with reduced biochemical recurrence rates following HDR-BT.

Methods: A total of 304 patients with high- or very-high-risk prostate cancer who underwent HDR-BT and EBRT were analyzed.

View Article and Find Full Text PDF

Color difference models (CDMs) are essential for accurate color reproduction in image processing. While CDMs aim to reflect perceived color differences (CDs) from psychophysical data, they remain largely untested in wide color gamut (WCG) and high dynamic range (HDR) contexts, which are underrepresented in current datasets. This gap highlights the need to validate CDMs across WCG and HDR.

View Article and Find Full Text PDF