Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study evaluates the Knoop microhardness of resin composites cured with different light-emitting diode (LED) based light curing units (LCU) or with a conventional quartz-tungsten-halogen light (QTH). Ten experimental groups with 10 specimens each were used. The specimens were prepared by placing two light-cured resin composites with similar VITA shade A2-microhybrid Filtek Z250/3M ESPE and microfill Durafil VS/Heraeus Kulzer--in a 2.0 mm-thick disc shaped mold. The specimens were polymerized for 40 seconds with the use of one QTH LCU (Optilux 501/Kerr-Demetron) and four LED LCUs: Elipar FreeLight 1 Cordless LED (3M ESPE), Ultrablue II LED with cord (DMC), Ultrablue III LED cordless (DMC) and LEC 470 I (MM Optics). Knoop microhardness was determined at the top and bottom surfaces of the specimens 24 hours following curing. Microhardness values in the microhybrid resin composite group showed no statistically significant differences when cured with LED FreeLight 1 LCU and QTH LCU (p<0.05). The other LED devices evaluated in the study presented lower microhardness values in both surfaces (p<0.05) when compared to QTH. In the microfill resin composite group, no statistically significant differences were observed among all LCUs evaluated on the bottom surfaces (p<0.05). However, on the top surfaces, QTH presented the highest KHN values, and the LED devices presented similar results when compared with KHN values relative to each other (p<0.05).
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!