Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of revision of the femoral component of a hip arthroplasty with use of an impaction bone-grafting technique and a cemented polished stem.

Methods: Thirty-three consecutive femoral reconstructions that were performed between March 1991 and February 1996 with use of the X-change femoral revision system, fresh-frozen morselized allograft, and a cemented polished Exeter stem were followed prospectively. Femoral bone stock defects were classified according to the Endoklinik classification. The average age of the patients at the time of the femoral component revision was sixty-three years. No patient was lost to follow-up, which was performed at a minimum of eight years, but eight patients had died. None of the deaths was related to the surgery.

Results: No femoral reconstruction had been rerevised at a mean of 10.4 years postoperatively. There was one unrecognized intraoperative fracture, which healed following nonoperative treatment. There were three postoperative femoral fractures, all through cortical defects at the level of the tip of the prostheses. All fractures healed after plate fixation, and all femoral implants were left in situ. The average subsidence of the stem within the cement mantle was 3 mm; seven stems migrated > or =5 mm. The average Harris hip score improved from 49 points prior to surgery to 85 points (range, 68 to 100 points) at the time of this review. Subsidence did not affect the Harris hip score. Kaplan-Meier analysis, with an end point of femoral revision for any reason, showed a survival rate of 100% (one-sided 95% confidence interval, 100% to 91.3%).

Conclusions: Femoral revision with use of an impaction bone-grafting technique and a cemented polished stem resulted in an excellent prosthetic survival rate at eight to thirteen years postoperatively. The major problem that occurred was a femoral fracture in four patients.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.D.02547DOI Listing

Publication Analysis

Top Keywords

cemented polished
16
femoral
12
femoral component
12
impaction bone-grafting
12
femoral revision
12
component revision
8
revision impaction
8
polished stem
8
bone-grafting technique
8
technique cemented
8

Similar Publications

Objective: Transcutaneous osseointegration prosthetic systems (TOPS) offer a stable skeletal attachment for artificial limbs post-extremity amputation, serving as an alternative to socket attachment. Press-fit osseointegration implants (OI) utilized in TOPS consistently enhance quality of life and mobility for amputees, particularly those experiencing socket-related issues. Despite notable benefits, late complications such as infection and implant loosening pose challenges unique to TOPS due to their percutaneous nature.

View Article and Find Full Text PDF

Coating Agents for Resin Composites: Effect on Color Stability, Roughness, and Surface Micromorphology Subjected to Brushing Wear.

Oper Dent

January 2025

*Roberta Tarkany Basting, DDS, MSc, PhD, Professor, Restorative Dentistry Department, Faculdade São Leopoldo Mandic, São Paulo, Brazil.

This study evaluated the influence of six resin composite coating agents on color stability and surface roughness after toothbrushing abrasion. Discs (Ø6 mm x 2 mm) of nanofilled resin composite (Filtek Z350XT) were prepared for application of coating agents (n=10): control (absence), two surface sealants (PermaSeal and BisCover LV), two adhesive systems (Scotchbond Multi-Purpose Adhesive/3M Oral Care and Single Bond Universal), and two modeling liquids (Modeling Resin and Composite Wetting Resin). CIELab*, WID, and color change (ΔEab, ΔE00, and ΔWID) were analyzed at baseline, after finishing and polishing, after application of coating agents, after coffee staining (simulating 30 days and one year of staining), and after toothbrushing abrasion.

View Article and Find Full Text PDF

Aims: The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems.

View Article and Find Full Text PDF

Background: Periprosthetic femoral fractures (PFF) are a challenging complication of hip arthroplasty surgery, posing a high risk of morbidity, mortality and reoperation. The Vancouver Classification describes a B2 PFF around a loose stem with sufficient bone stock. In recent years, the number of B2 PFFs and cementation of femoral stems have increased substantially.

View Article and Find Full Text PDF

Aim: To compare the microleakage of three bulk-fill composite resins with or without resin-modified glass ionomer cement (RMGIC) liner.

Materials And Methods: A total of 30 maxillary human 1st premolar teeth were selected. Two box preparations were made on the mesial and distal sides.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!