We demonstrate that magnetization transfer contrast can be used to improve the diagnostic utility of fat-suppressed steady-state three-dimensional gradient-recalled images. Fat suppression is achieved using a "jump-return" pair of contiguous shaped pulses. No time interval exists between the pulses, and no RF echo is generated. The sequence normally produces images with "density" weighting. Preparation of the spin magnetization with off-resonance frequency-selective excitation creates magnetization transfer contrast which attenuates signal intensity in proportion to the exchange rate of magnetization from free water with magnetization from water bound to macromolecules or protons that have restricted mobility. The resulting images have excellent fat suppression with low sensitivity to motion since no subtraction is used. In addition, the mechanism of signal attenuation is independent of paramagnetic effects, and addition of Gd-DTPA produces signal enhancement from vascularized regions of tissue. Examples are presented for the knee and breast, where the observation of pathology with signal enhancement from Gd-DTPA is improved over conventional 3D fat-suppressed images.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.1910260113DOI Listing

Publication Analysis

Top Keywords

magnetization transfer
12
transfer contrast
12
fat-suppressed steady-state
8
steady-state three-dimensional
8
fat suppression
8
signal enhancement
8
magnetization
6
images
5
contrast fat-suppressed
4
three-dimensional images
4

Similar Publications

Ultra-high-resolution brain MRI at 0.55T: bSTAR and its application to magnetization transfer ratio imaging.

Z Med Phys

January 2025

Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland.

Purpose: This study aims to evaluate the feasibility of structural sub-millimeter isotropic brain MRI at 0.55 T using a 3D half-radial dual-echo balanced steady-state free precession sequence, termed bSTAR and to assess its potential for high-resolution magnetization transfer imaging.

Methods: Phantom and in-vivo imaging of three healthy volunteers was performed on a low-field 0.

View Article and Find Full Text PDF

Defects Calculation and Accelerated Interfacial Charge Transfer in a Photoactive MOF-Based Heterojunction.

Small

January 2025

Institutes of Physical Science and Information Technology, Anhui Graphene Carbon Fiber Materials Research Center, Anhui University, Hefei, Anhui, 230601, P. R. China.

Photocatalytic hydrogen production is currently considered a clean and sustainable route to meet the energy and environmental issues. Among, heterojunction photocatalysts have been developed to improve their photocatalytic efficiency. Defect engineering of heterojunction photocatalysts is attractive due to it can perform as electron trap and change the band structure to optimize the interfacial separation rate of photogenerated electron-hole pairs.

View Article and Find Full Text PDF

Background: The presence of diffuse brain damage in normal-appearing white matter (NAWM) and gray matter (NAGM) in neuromyelitis optica spectrum disorder (NMOSD) remains controversial. We aimed to address this controversy by applying a multiparametric MRI approach. Additionally, the association between MRI metrics and clinical variables was explored.

View Article and Find Full Text PDF

Cases: Two patients with spontaneous loss of thumb interphalangeal joint extension were referred after history, electrodiagnostic, and/or magnetic resonance imaging (MRI) findings were felt to demonstrate a posterior interosseous nerve (PIN) palsy. Subsequent physical examination and additional directed studies suggested an alternative explanation: rupture of the extensor pollicis longus (EPL) tendon, subsequently confirmed at surgery. An extensor indicis proprius to EPL transfer restored thumb function.

View Article and Find Full Text PDF

Nonstoichiometric pseudoprotic ionic liquids (NPPILs) are an emerging class of ionic liquids with interesting physical properties and intriguing prospects for technological applications. However, fundamental questions remain about the proton transfer equilibria that underlie their ionic character. We use a combination of nuclear magnetic resonance spectroscopy, infrared spectroscopy, and small-angle X-ray scattering to characterize the equilibria of trihexylamine/butyric acid and water/butyric acid mixtures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!