A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of metformin and gliclazide in human plasma by liquid chromatography-tandem mass spectrometry: application to a bioequivalence study of two formulations in healthy volunteers. | LitMetric

A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine gliclazide and metformin in human plasma using huperzine A as the internal standard (IS). After acetonitrile-induced protein precipitation of the plasma samples, gliclazide, metformin and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of 2.0 min and linear calibration curves over the concentration ranges of 10-10,000 ng ml(-1) for gliclazide and 7.8-4678.9 ng ml(-1) for metformin. The recoveries of the method were found to be 71-104%. The lower limits of quantification (LOQ) of the method were 10.0 and 7.8 ng ml(-1) for gliclazide and metformin, respectively. The intra- and interday precision was less than 15% for all quality control samples at concentrations of 100, 500, and 2000 ng ml(-1). The validated LC/MS/MS method has been used to study bioequivalence in healthy volunteers. These results indicate that the method was efficient with a very short running time (2.0 min) for metformin and gliclazide compared to the methods reported in the literature. The presented method had acceptable accuracy, precision and sensitivity and was used in clinical bioequivalence study.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jms.907DOI Listing

Publication Analysis

Top Keywords

gliclazide metformin
12
metformin gliclazide
8
human plasma
8
mass spectrometry
8
bioequivalence study
8
healthy volunteers
8
lc/ms/ms method
8
running time
8
time min
8
ml-1 gliclazide
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!