A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurements of regional alveolar oxygen pressure using hyperpolarized 3He MRI. | LitMetric

Rationale And Objectives: The aim of this work is to review hyperpolarized (HP) helium-3 (3He) magnetic resonance imaging (MRI) methods to measure regional alveolar oxygen partial pressure (P(A)O2) and oxygen depletion rate (R) in the lung. We point out limitations of the methods and suggest improvements to increase their accuracy.

Materials And Methods: P(A)O2 and R can be extracted from series of HP gas images acquired during breath hold by making use of the depolarizing effect of oxygen on HP gas. To separate oxygen-induced depolarization from other depolarizing effects, several techniques can be used. We review currently used techniques and point out their advantages and limitations.

Results: We show that the precision of oxygen measurements depends on a variety of parameters and can vary within the measurement volume. Accuracy of the measurement also can be influenced by diffusion of oxygen and polarized 3He and generally is different for single-slice and multislice measurements. We present numerical simulations, phantom data, and in vivo data for illustration.

Conclusion: HP 3He MRI is a noninvasive, nonionizing, and repeatable imaging method that allows for quantitative analysis of lung function. The current techniques for measuring P(A)O2 have the potential to deliver clinically relevant functional images.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2005.07.007DOI Listing

Publication Analysis

Top Keywords

regional alveolar
8
alveolar oxygen
8
3he mri
8
oxygen
6
measurements regional
4
oxygen pressure
4
pressure hyperpolarized
4
3he
4
hyperpolarized 3he
4
mri rationale
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!