Purpose: To evaluate the potential importance of radioactive 9C-ion beam in cancer radiotherapy.

Methods And Materials: Human salivary gland (HSG) cells were exposed to a double-radiation-source 9C beam at different depths around the Bragg peak. Cell survival fraction was determined by standard clonogenic assay. For comparison, the same experiment was conducted for a therapeutic 12C beam. To determine relative biologic effectiveness (RBE) values, HSG cells were also irradiated with 60Co gamma-rays of fractionation scheme as the reference.

Results: The 9C beam was more efficient in cell killing at the depths around its Bragg peak than was the 12C beam, which corresponded to the 9C-ion stopping region and where delayed low-energy particles were emitted. The RBE value at 50% survival level for the 9C beam varied from 1.38 to 4.23. Compared with the 12C beam, the RBE values for the 9C beam were always higher; an increase in RBE by a factor of up to 1.87 has been observed at the depths distal to the Bragg peak.

Conclusion: The potential advantage of radioactive 9C-ion beam in cancer therapy has been revealed at low dose rate in comparison with a therapeutic 12C beam. This observation, however, remains to be investigated at therapeutic dose rates in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2005.08.006DOI Listing

Publication Analysis

Top Keywords

12c beam
16
depths bragg
12
bragg peak
12
radioactive 9c-ion
12
9c-ion beam
12
beam
11
cell killing
8
beam cancer
8
hsg cells
8
therapeutic 12c
8

Similar Publications

the recently developed V79-RBEbiological weighting function (BWF) model is a simple and robust tool for a fast relative biological effectiveness (RBE) assessment for comparing different exposure conditions in particle therapy. In this study, the RBEderived by this model (through the particle and heavy ion transport code system (PHITS) simulatedspectra) is compared with values of RBEusing experimentally derivedspectra from a silicon-on-insulator (SOI) microdosimeter.experimentally measuredspectra are used to calculate an RBEvalue utilizing the V79-RBEBWF model as well as the modified microdosimetric kinetic model (MKM) to produce an RBE-vs-trend for a wide range of ions.

View Article and Find Full Text PDF

FLASH Bragg-Peak Irradiation With a Therapeutic Carbon Ion Beam: First In Vivo Results.

Int J Radiat Oncol Biol Phys

November 2024

GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Darmstadt, Germany; Life Science Engineering Department, Technische Hochschule Mittelhessen, Gießen, Germany.

Purpose: In recent years, ultra-high dose rate (UHDR) irradiation has emerged as a promising innovative approach to cancer treatment. Characteristic feature of this regimen, commonly referred to as FLASH effect, demonstrated primarily for electrons, photons, or protons, is the improved normal tissue sparing, whereas the tumor control is similar to the one of the conventional dose-rate (CDR) treatments. The FLASH mechanism is, however, unknown.

View Article and Find Full Text PDF

Purpose: This study aims to validate the Light-Ion Quantum Molecular Dynamics (LIQMD) model, an advanced version of the QMD model for more accurate simulations in hadron therapy, incorporated into Geant4 (release 11.2).

Methods: Two sets of experiments are employed.

View Article and Find Full Text PDF

Carbon-ion irradiation is increasingly used at the skull base and spine near the radiation-sensitive spinal cord. To better characterize the in vivo radiation response of the cervical spinal cord, radiogenic changes in the high-dose area were measured in rats using magnetic resonance imaging (MRI) diffusion measurements in comparison to conventional photon irradiations. In this longitudinal MRI study, we examined the gray matter (GM) of the cervical spinal cord in 16 female Sprague-Dawley rats after high-dose photon (n = 8) or carbon-ion (12C) irradiation (n = 8) and in 6 sham-exposed rats until myelopathy occurred.

View Article and Find Full Text PDF

Background And Purpose: The effort to translate clinical findings across institutions employing different relative biological effectiveness (RBE) models of ion radiotherapy has rapidly grown in recent years. Nevertheless, even for a chosen RBE model, different implementations exist. These approaches might consider or disregard the dose-dependence of the RBE and the radial variation of the radiation quality around the beam axis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!