Atmospheric compensation with a speckle beacon in strong scintillation conditions: directed energy and laser communication applications.

Appl Opt

Intelligent Optics Laboratory, Institute for Systems Research, University of Maryland, College Park, Maryland 20742, USA.

Published: October 2005

Wavefront control experiments in strong scintillation conditions (scintillation index, approximately equal to 1) over a 2.33 km, near-horizontal, atmospheric propagation path are presented. The adaptive-optics system used comprises a tracking and a fast-beam-steering mirror as well as a 132-actuator, microelectromechanical-system, piston-type deformable mirror with a VLSI controller that implements stochastic parallel gradient descent control optimization of a system performance metric. The experiments demonstrate mitigation of atmospheric distortions with a speckle beacon typical for directed energy and free-space laser communication applications.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.44.006388DOI Listing

Publication Analysis

Top Keywords

speckle beacon
8
strong scintillation
8
scintillation conditions
8
directed energy
8
laser communication
8
communication applications
8
atmospheric compensation
4
compensation speckle
4
beacon strong
4
conditions directed
4

Similar Publications

A new protocol for a single-stage combined cardiopulmonary and echocardiography exercise test: a pilot study.

Eur Heart J Imaging Methods Pract

January 2024

Children's Health and Exercise Research Centre (CHERC), Public Health and Sports Sciences, Faculty of Life and Health Sciences, University of Exeter Medical School, St Luke's Campus, Heavitree Road, Exeter EX1 2LU, UK.

Aims: The value of cardiopulmonary exercise testing (CPET) and exercise stress echocardiography (ESE) in managing cardiac disease is well known, but no standard CPET-ESE protocol is currently recommended. This pilot study aims to compare feasibility and cardiac function responses between a new high-intensity single-stage combined test (CPET-hiESE) and a standard maximal ESE (smESE).

Methods And Results: After screening and maximal CPET, all volunteers ( = 21) underwent three ESE modalities: (i) based on the gas exchange threshold (hiESE-GET, 40% of peak-GET, 6 min), (ii) based on heart rate (HR) (hiESE-HR, 80% of peak HR, 6 min), and (iii) smESE (85% of predicted peak HR for age, 3 min).

View Article and Find Full Text PDF

Adaptive optics (AO) compensation for imaging or coherent illumination of a remote object relies on accurate sensing of atmospheric aberrations. When a coherent beacon is projected onto the object to enable wavefront sensing, the reflected reference wave will exhibit random variation in phase and amplitude characteristics of laser speckle. In a Shack-Hartmann wavefront sensor (SHWFS) measurement, speckle effects cause fluctuations in the intensity of focal spots and errors in the position of their centroids relative to those expected from purely atmospheric phase aberrations.

View Article and Find Full Text PDF

Adaptive-optics (AO) systems correct the optical distortions of atmospheric turbulence to improve resolution over long paths. In applications such as remote sensing, object tracking, and directed energy, the AO system's beacon is often an extended beacon reflecting off an optically rough surface. This situation produces speckle noise that can corrupt the wavefront measurements of the AO system, degrading its correction of the turbulence.

View Article and Find Full Text PDF

Multimode fiber endoscopes have recently been shown to provide sub-micrometer resolution, however, imaging through a multimode fiber is highly sensitive to bending. Here we describe the implementation of a coherent beacon source placed at the distal tip of the multimode fiber, which can be used to compensate for the effects of bending. In the first part of this paper, we show that a diffraction limited focused spot can be generated at the distal tip of the multimode fiber using the beacon.

View Article and Find Full Text PDF

Advanced methods in fluorescence microscopy.

Stud Health Technol Inform

April 2014

Core Imaging Facility, New Jersey Medical School, UM, NJ, USA.

It requires a good deal of will power to resist hyperbole in considering the advances that have been achieved in fluorescence microscopy in the last 25 years. Our effort has been to survey the modalities of microscopic fluorescence imaging available to cell biologists and perhaps useful for diagnostic pathologists. The gamut extends from established confocal laser scanning through multiphoton and TIRF to the emerging technologies of super-resolution microscopy that breech the Abbe limit of resolution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!