Background: The dose-dependent suppression of midlatency auditory evoked potentials by general anesthetics has been proposed to measure depth of anesthesia. In this study, perioperatively recorded midlatency auditory evoked potentials were analyzed in a time-frequency space to identify significant changes induced by general anesthesia.

Methods: Perioperatively recorded auditory evoked potentials of 19 patients, recorded at varying levels of anesthesia, were submitted to a multiscale analysis using the wavelet analysis. Energy contents of the signal were calculated in frequency bands 0-57.1 Hz, 57.1-114.3 Hz, 114.3-228.6 Hz, and 228.6-457.1 Hz. A Friedman test and a Dunn multiple comparisons test were performed to identify significant differences.

Results: Statistical evaluation showed a highly significant decrease of the wavelet energies for the frequency bands 57.1-114.3 Hz (P < 0.0001), 114.3-228.6 Hz (P < 0.0001), and 228.6-457.1 Hz (P < 0.0001) for the measuring points representing deep general anesthesia. This decrease is accompanied by a decrease in the wavelet energy of the frequency band 0-57.1 Hz of no statistical significance (P = 0.021) (level of significance set to P = 0.01). The changes are most prominent in the poststimulus interval between 10 and 30 ms.

Conclusions: This study describes the presence of high-frequency components of the auditory evoked potential. The amount of these components is higher during responsiveness when compared to unconsciousness. Temporal localization of the high-frequency components within the auditory evoked potential shows that they represent a response to the auditory stimulus. Further studies are required to identify the source of these high-frequency components.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000542-200511000-00007DOI Listing

Publication Analysis

Top Keywords

auditory evoked
24
high-frequency components
16
evoked potentials
16
components auditory
12
midlatency auditory
8
perioperatively recorded
8
frequency bands
8
decrease wavelet
8
evoked potential
8
auditory
7

Similar Publications

Evoked potential metrics extracted from an EEG exam can provide novel sources of information regarding brain function. While the P300 occurring around 300 ms post-stimulus has been extensively investigated in relation to mild cognitive impairment (MCI), with decreased amplitude and increased latency, the P200 response has not, particularly in an oddball-stimulus paradigm. This study compares the auditory P200 amplitudes between MCI (28 patients aged 74(8)) and non-MCI, (35 aged 72(4)).

View Article and Find Full Text PDF

Background: Understanding the genetic etiology of Alzheimer's disease (AD) has been a major focus of research in neurodegenerative diseases. Amid the three common allelic variants of the apolipoprotein E (APOE) gene in humans, called APOE ε2, ε3 and ε4, the ε4 allele is the most common genetic risk factor for late-onset AD, being found in 20% of the world population.

Method: We used Event-Related Potentials (ERP) and Event-Related Spectral Perturbation (ERSP) as features for classification of apolipoprotein E ϵ4 (APOE ε4) allele carriers in AD patients and healthy controls.

View Article and Find Full Text PDF

The 22q11.2 deletion is a risk factor for multiple psychiatric disorders including schizophrenia and also increases vulnerability to middle-ear problems that can cause hearing impairment. Up to 60% of deletion carriers experience hearing impairment and ~30% develop schizophrenia in adulthood.

View Article and Find Full Text PDF

Purpose: Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences.

Methods: Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study.

View Article and Find Full Text PDF

Repairbads: An automatic and adaptive method to repair bad channels and segments for OPM-MEG.

Neuroimage

January 2025

Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China; State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China; Hefei National Laboratory, Hefei, 230088, China. Electronic address:

The optically pumped magnetometer (OPM) based magnetoencephalography (MEG) system offers advantages such as flexible layout and wearability. However, the position instability or jitter of OPM sensors can result in bad channels and segments, which significantly impede subsequent preprocessing and analysis. Most common methods directly reject or interpolate to repair these bad channels and segments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!