Objective: Our study was a prospective in vivo study to evaluate whether MR angiography is suitable for assessing stent patency and grading in-stent stenoses and to examine whether the accuracy of MR angiography changes with time after stent implantation.

Subjects And Methods: In a prospective study, 34 iliac stenoses in 27 patients were treated by implantation of 35 nitinol stents. MR angiography was performed immediately after stent placement for 32 stents, and both digital subtraction angiography (DSA) and MR angiography were repeated at the 6-month follow-up for 23 stents. Three blinded observers assessed stent patency and the degree of in-stent stenoses on MR angiography and DSA (the standard of reference) images. The difference between the observers' grading of stenoses on DSA and on MR angiography was determined. Statistical analysis was performed using the Student's t test for paired samples.

Results: Stent patency was assessed correctly for all stents and both sets of MR angiography images. Evaluation of DSA 1 images (obtained at end of implantation procedure) revealed that 96.9% of in-stent stenoses were less than 50%. On DSA 2 images (obtained at follow-up), 95.7% of in-stent stenoses were graded as less than 50%. The difference between grading of stenoses on DSA and MR angiography images was 15.0% +/- 16.0% (minimum, 0.0%; maximum, 63.3%) for DSA 1 versus MR angiography 1 (statistically significant, p = 0.037) and 9.8% +/- 13.5% (minimum, 0.0%; maximum, 63.3%) for MR angiography 2 versus DSA 2 (not statistically significant, p = 0.355).

Conclusion: Patency was correctly assessed for all stents on MR angiography. The quality of MR angiography regarding characterization of in-stent stenoses improved with time after stent placement. However, discrepancies of more than 60% between grading of lumen narrowing on DSA and MR angiography images occurred even at the 6-month follow-up. Thus, MR angiography is not yet a reliable technique for characterization of in-stent stenoses.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.04.1389DOI Listing

Publication Analysis

Top Keywords

in-stent stenoses
28
angiography
16
dsa angiography
16
stent patency
12
angiography images
12
stenoses
10
dsa
9
implantation nitinol
8
nitinol stents
8
time stent
8

Similar Publications

Predictors and Long-Term Prognostic Significance of Bailout Stenting During Percutaneous Coronary Interventions With Sirolimus-Coated Balloon: A Subanalysis of the Eastbourne Study.

Am J Cardiol

December 2024

DCB Academy, Milano, Italy; Fondazione Ricerca e Innovazione Cardiovascolare, Milano, Italy; University Hospitals Cleveland Medical Center, Cleveland, Ohio; Case Western Reserve University School of Medicine, Cleveland, Ohio. Electronic address:

Percutaneous coronary intervention (PCI) with drug-coated balloon (DCB) has been expanding progressively in recent years. Convincing evidence demonstrated the ability of some DCB to promote positive vessel remodeling, with potential clinical benefits at follow-up. When PCI with DCB results in suboptimal angiographic results (residual stenosis >30% or type C to F dissection), bailout stenting (BS) implantation is recommended to mitigate the risk of abrupt vessel occlusion or restenosis.

View Article and Find Full Text PDF

Background: Intravascular ultrasound-determined plaque protrusion (PP) during carotid artery stenting (CAS) using conventional stents is reported in 7.6% to 12% of cases and is associated with periprocedural cerebral embolism. The Casper/Roadsaver stent (CRS) is a dual-layer micromesh stent designed to reduce the risk of PP, with a mesh cell diameter 4-fold smaller size than that of conventional stents.

View Article and Find Full Text PDF

Background: In-stent restenosis (ISR) is the primary cause of stroke recurrence after intracranial stenting. Drug-eluting stents (DES) have recently shown great potential for reducing restenosis. This systematic review aimed to evaluate the efficacy and safety of DES compared with bare-metal stents (BMS) for intracranial atherosclerotic stenosis (ICAS).

View Article and Find Full Text PDF

Prognosis and Management of Recurrent Stenosis After Pulmonary Vein Stenting: A Prospective Study.

JACC Clin Electrophysiol

November 2024

Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Electronic address:

Background: Pulmonary vein stenting is effective for severe pulmonary vein stenosis, which is limited by restenosis. The assessment and management of in-stent restenosis (ISR) are inadequate, and follow-up outcomes after reintervention remain unknown.

Objectives: This study aimed to assess the prognosis and management of pulmonary vein ISR and determine whether the modified stent-in-stent strategy is superior to balloon angioplasty (BA) in treating ISR.

View Article and Find Full Text PDF

Background: In-stent restenosis (ISR) is a crucial factor that affects the long-term efficacy of intracranial bare metal stent (BMS) implantation for intracranial atherosclerotic stenosis (ICAS). Patients with intracranial ISR are at a high risk of recurrent ischaemic events. The NOVA intracranial drug-eluting stent (DES) trial demonstrates that a DES can reduce ISR and stroke recurrence after intracranial bare stent implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!